ACCESSORIES —

Condensing Unit

Low Ambient Kit  913549A- 

Maintains system 

pressures during low ambient conditions.

PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS
10.1 EER —High Effi ciency — Three Phase

COPPER WIRE SIZE — AWG

(1% Voltage Drop)

Supply Wire Length-Feet

Supply Circuit

200

150

100

50

Ampacity

6

8

10

14

15

4

6

8

12

20

4

6

8

10

25

4

4

6

10

30

3

4

6

8

35

3

4

6

8

40

2

3

4

6

45

2

3

4

6

50

2

3

4

6

55

1

2

3

4

60

Model No. T3BN-

090C

090W

120C

120W

Electrical Data

Volts-Phase-Hz

280/230-3-60

460-3-60

280/230-3-60

460-3-60

380/420-3-50

380/420-3-50

Voltage Range (Min-Max)

187-253

414-506

187-253

414-506

Total Amps

32.1

16.4

33.4

17.2

Min Circuit Ampacity

41.4

21.7

43

22.7

Delay Fuse Max. (1)

60

35

70

35

Wire Size/Max Length (AWG 60°C Cu)

4/100

8/100

4/100

8/100

Wire Size/Max Length (AWG 75°C Cu)

6/100

8/100

4/100

8/100

Component Data

Coil

Area (ft^2)

31.94

31.94

31.94

31.94

Rows-FPI

2-16

2-16

2-18

2-18

Tube Dia.

3/8” OD

3/8” OD

3/8” OD

3/8” OD

Fan Motor

Volts-Phase-Hz

280/230-3-60

460-3-60

280/230-3-60

460-3-60

380/420-3-50

380/420-3-50

Qty

1

1

1

1

Horsepower

3/4

3/4

3/4

3/4

Full Load Amps

3.3

1.7

3.3

1.7

Fan Blade

Dia./Pitch/#Blades

30/19/3

30/19/3

30/26/3

30/26/3

RPM/CFM (Max-Total)

825/7500

825/7500

825/8500

825/8500

Compressor 
Data

Volts-Phase-Hz

280/230-3-60

460-3-60

280/230-3-60

460-3-60

Qty./Type

1 / Scroll

1 / Scroll

1 / Scroll

1 / Scroll

RLA

28.8

14.7

30.1

15.5

LRA

195

95

225

114

Stages/Percent

1 / 100

1 / 100

1 / 100

1 / 100

Crankcase Heater Qty./Type

1 / Band

1 / Band

1 / Band

1 / Band

Refrigerant Suction Line-Length/O.D. 

0 - 15 ft.

1 1/8”

1 1/8”

1 1/8”

1 1/8”

(Liq. Line All Lengths  - 5/8” O.D.) 
Circuits (Qty) - 1

16 - 25 ft

1 3/8” 

(3)

1 3/8” 

(3)

1 3/8” 

(3)

1 3/8” 

(3)

26 - 75 ft.

1 3/8” 

(3)

1 3/8” 

(3)

1 3/8” 

(3)

1 3/8” 

(3)

Refrigerant Charge

Holding Charge

56

56

90

90

R-22 Ounces

Total System with 15’ Line Set 

(2)

374

374

486

486

Weight

Net

413

413

423

423

Approximate (lbs.)

Ship

425

425

435

435

(1)

 HACR Type Circuit Breakers may be used.

(2)

 Add 9.0 oz. of refrigerant per 5 feet of additional line set.

(3)

 Requires a 1-3/8” to  1-1/8” reducer line to unit.

Summary of Contents for T3BN

Page 1: ...ation of heating and or air conditioning appliances Some local codes require licensed installation service personnel for this type of equipment Read all instructions carefully before starting the inst...

Page 2: ...e heat in place of the heat pump will result in an increase in electric utility costs Defrost During cold weather heating operation the outdoor unit may develop a coating of snow and ice on the heat t...

Page 3: ...defrost cycle the outdoor fanwillstop andthecompressorwillcontinue to run and heat the outdoor coil causing the snow and ice to melt After the snow and ice have melted some steam may rise from the out...

Page 4: ...his equipment follow all precautions in the literature on tags and on labels provided with theequipment Readandthoroughlyunderstand theinstructionsprovidedwiththeequipmentprior to performing the insta...

Page 5: ...bMount Thesiteselectedforaslabmount installation requires a stable foundation and one not subject to erosion The slab should be level and anchored if necessary prior to placing the equipment on the sl...

Page 6: ...ze based on N E C for 60 type copper conductors COPPER WIRE SIZE AWG 1 Voltage Drop Supply Wire Length Feet Supply Circuit 200 150 100 50 Ampacity 6 8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30 3 4...

Page 7: ...hermostat R Air Handler Heat Pump OD Section Typical Heat Pump with Standard Air Handler O NOTE Jumper betweenW2 and E is required when no OD T Stat is used C W2 to be connected to Electric Heat Y W2...

Page 8: ...inimumoffiveminutes increase the setpoint temperature of the thermostat to the maximumsetting Verifythattheoutdoorunitand indoor blower have energized Feel the air being circulated by the indoor blowe...

Page 9: ...delay Reciprocating compressors should only use this setting in conjunction with an approved hard start kit Scroll compressors thathavenoiseissueswhilegoingintoorcoming out of defrost should use this...

Page 10: ...7 5 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature F Liquid Pressure psig Add refrigerant when below curve Remo...

Page 11: ...10 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature F Liquid Pressure psig Add refrigerant when below curve Remov...

Page 12: ...Temp Press Press Temp Press Press Temp Press Press Temp Press Press Temp 19 134 135 20 140 135 21 146 136 22 152 136 32 162 157 51 199 198 61 248 179 20 141 133 21 146 133 22 151 134 23 156 134 33 169...

Page 13: ...ons for control circuit and optional Relay Transformer Kits 1 Couper le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de...

Page 14: ...8 2 18 Tube Dia 3 8 OD 3 8 OD 3 8 OD 3 8 OD Fan Motor Volts Phase Hz 280 230 3 60 460 3 60 280 230 3 60 460 3 60 380 420 3 50 380 420 3 50 Qty 1 1 1 1 Horsepower 3 4 3 4 3 4 3 4 Full Load Amps 3 3 1 7...

Page 15: ...15...

Page 16: ...AVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER 708538G 708538A 708538A replaces 7085380 Specifications and illustrations subject to change without notice and without incurring obligations Prin...

Reviews: