Nordyne T3BN User'S Information And Installation Instructions Manual Download Page 13

13

RELA

Y

4

2

3

1

6

5

T1

T2

T3

CCH

C

S

R

T1

T2

C

Y

O

W

2

R

DFT

DF1

DF2

E

DEFR

OST

CONTR

OL

BO

ARD

CY

O

W

2

R

E

L3

L2

L1

GRD

REV

VA

LV

E

DFT

LO

W PRESSURE

SWITCH

THREE PHASE

FIELD SUPPL

Y

CAP

A

CIT

OR

CONT

A

C

T

O

R

OUTDOOR

F

AN 

M

OTO

R

COMPRESSOR

HIGH PRESSURE

SWITCH

T1

L1

L2

L3

T2

T3

ORANGE

GRA

Y

BLA

CK HARNESS

RED HARNESS

GRA

Y

YELLO

W HARNESS

BLA

CK

BLA

CK

BLACK

PURPLE

ORANGE

BLACK

WHITE

BLACK

BLUE

BLUE

BR

O

W

N

BLA

CK

GREEN

RED

Split System Heat Pump

Three Phase

GRAM

NO

TES:

1.

 Disconnect all po

wer bef

o

re servicing.

2.

 For suppl

y connections use copper conductor

s

 onl

y

.

3.

 Not suitable on systems that e

x

ceed 150 v

olts to gr

ound.

4.

 For replacement wires use conductor

s

 suitable f

o

r 105°C

5.

 For suppl

y wire ampacities and o

v

er

current pr

otection,

 see unit data label.

6.

 Connect to 24 v

a

c/40v

a/c

lass 2 cir

c

uit.

  See furnace/air handler installation

    instructions f

o

r contr

ol cir

c

uit and optional Rela

y/T

ransf

ormer Kits.

1.

 Couper le courant a

v

ant de faire letretien.

2.

 Emplo

yez uniquement des conducteur

s en cuivre

3.

 Ne con

v

ient pas aux installations de plus de 150 v

olt a la terre

.

FIELD WIRING

LEGEND:

LO

W V

O

LT

A

G

E

HIGH V

O

LT

A

G

E

L1

L2

L3

CCH

CC

OUTDOOR

F

A

N MO

T

O

R

CAP

A

CIT

OR

RELA

Y

COMPRESSOR

CC

L2

L1

L3

C

S

R

CC

T3

T3

E

2

4

1

1

3

R

W2

O

Y

C

LOGIC

DEFR

OST CONTR

OL

BO

ARD

DEFR

OST BO

ARD OPERA

TION

1)Closes dur

ing defrost.

  

   Rating:

 1 Amp

. Max.

2)Opens dur

ing defrost.

  

   Rating:

 2 HP

. at 230 

V

a

c Max.

3)Closed when 

“Y”

 is on.

 Open 

   when 

“Y”

 is off

.  Pro

vides 

“off

” 

   dela

y time of 5 mins

. when

   

“Y”

 opens

.

4)With DFT closed and 

“Y”

 closed, compressor r

u

n time is 

   accumulated.

  Opening of DFT dur

ing defrost or inter

v

a

l

   per

iod resets the inter

v

al to 0.

5)Ground on location pro

vided inside compressor

   ter

minal bo

x.

LO

W V

O

L

T

A

G

E

TERMINAL

LPS

HPS

RV

S

DFT

DFT

DF2

DF1

R

W2

O

Y

C

T2

T1

CC

CC - Contactor Coil

CCH - Crankcase Heat

DFT - Defrost 

Ther

mostat

R

VS - Re

v

ersing 

V

alv

e Selenoid

LPS - Lo

w Pressure Switch

HPS - High Pressure Switch

7106060

Summary of Contents for T3BN

Page 1: ...ation of heating and or air conditioning appliances Some local codes require licensed installation service personnel for this type of equipment Read all instructions carefully before starting the inst...

Page 2: ...e heat in place of the heat pump will result in an increase in electric utility costs Defrost During cold weather heating operation the outdoor unit may develop a coating of snow and ice on the heat t...

Page 3: ...defrost cycle the outdoor fanwillstop andthecompressorwillcontinue to run and heat the outdoor coil causing the snow and ice to melt After the snow and ice have melted some steam may rise from the out...

Page 4: ...his equipment follow all precautions in the literature on tags and on labels provided with theequipment Readandthoroughlyunderstand theinstructionsprovidedwiththeequipmentprior to performing the insta...

Page 5: ...bMount Thesiteselectedforaslabmount installation requires a stable foundation and one not subject to erosion The slab should be level and anchored if necessary prior to placing the equipment on the sl...

Page 6: ...ze based on N E C for 60 type copper conductors COPPER WIRE SIZE AWG 1 Voltage Drop Supply Wire Length Feet Supply Circuit 200 150 100 50 Ampacity 6 8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30 3 4...

Page 7: ...hermostat R Air Handler Heat Pump OD Section Typical Heat Pump with Standard Air Handler O NOTE Jumper betweenW2 and E is required when no OD T Stat is used C W2 to be connected to Electric Heat Y W2...

Page 8: ...inimumoffiveminutes increase the setpoint temperature of the thermostat to the maximumsetting Verifythattheoutdoorunitand indoor blower have energized Feel the air being circulated by the indoor blowe...

Page 9: ...delay Reciprocating compressors should only use this setting in conjunction with an approved hard start kit Scroll compressors thathavenoiseissueswhilegoingintoorcoming out of defrost should use this...

Page 10: ...7 5 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature F Liquid Pressure psig Add refrigerant when below curve Remo...

Page 11: ...10 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature F Liquid Pressure psig Add refrigerant when below curve Remov...

Page 12: ...Temp Press Press Temp Press Press Temp Press Press Temp Press Press Temp 19 134 135 20 140 135 21 146 136 22 152 136 32 162 157 51 199 198 61 248 179 20 141 133 21 146 133 22 151 134 23 156 134 33 169...

Page 13: ...ons for control circuit and optional Relay Transformer Kits 1 Couper le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de...

Page 14: ...8 2 18 Tube Dia 3 8 OD 3 8 OD 3 8 OD 3 8 OD Fan Motor Volts Phase Hz 280 230 3 60 460 3 60 280 230 3 60 460 3 60 380 420 3 50 380 420 3 50 Qty 1 1 1 1 Horsepower 3 4 3 4 3 4 3 4 Full Load Amps 3 3 1 7...

Page 15: ...15...

Page 16: ...AVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOWNER 708538G 708538A 708538A replaces 7085380 Specifications and illustrations subject to change without notice and without incurring obligations Prin...

Reviews: