6
a.
Federal Manufactured Home Constructions & Safety
Standard (H.U.D. Title 24, Part 3280.707[a][2])
b.
American National Standard (ANSI-119.2/NFPA-501C)
for all recreational vehicle installations.
c.
American National Standard (ANSI-Z223.1/NFPA-54)
and/or CAN/CGA B149 for all gas-fired furnace models.
d.
American National Standard (ANSI-Z95.1/NFPA-31) and/
or CSA B139 for all oil-fired furnace models.
e.
American National Standard (ANSI-C1/NFPA-70) and/or
CSA 22.1 Canadian Electric Code Part 1 for all electrical
field wiring.
f.
Units have been investigated under standards UL 307A
& B, ANZI 21.47a — CAN/2.3a - 1995, and CSA B140.10.
2. CIRCULATING AIR SUPPLY
RETURN AIR PROVISIONS
U.S.A. home manufacturers shall comply with all of the
following conditions to have acceptable return air systems for
closet installed forced air heating appliances:
a.
Regardless of the location, the return air opening into the
closet shall not be less than specified in the appliance’s
listing.
b.
Means shall be provided to prevent inadvertent closure
by a flat object placed over the return air opening when it
is located in the floor of the closet (versus the vertical front
or side wall).
c.
The cross-sectional area of the return duct system lead-
ing into the closet, when located in the floor or ceiling shall
not be less than 235 square inches (or 390 square inches
for 5 ton ready M1 Furnaces).
d.
The total free area of openings in the floor or ceiling
registers serving the return air duct system must be at
least 352 sq. in. At least one register should be located
where it is not likely to be covered by carpeting, boxes and
other objects.
e.
Materials located in the return duct system must have a
flame spread classification of 200 or less. This includes a
closet door if the furnace is in a closet.
f.
Noncombustible pans having 1" upturned flanges are
located beneath openings in a floor duct system.
Table 2. Blower Performance Data
ESP
(In. W.C.)
Low
Med-Lo Med-Hi
High
Low
Med-Lo Med-Hi
High
1/8 HP
1
024
0.1
820
730
9 X 7.5
0.2
790
680
0.3
720
610
056 - H, A
0.4
650
550
UNITS
0.5
560
450
0.6
430
330
1/5 HP
1
030
0.1
950
850
9 X 7.5
0.2
910
810
066-A
0.3
850
730
070 - H,A
0.4
780
670
UNITS
0.5
680
580
0.6
570
480
1/4 HP
1
036
0.1
1210
1140
10 x 8
0.2
1190
1110
077 - H, B
0.3
1140
1050
090 - H, B
0.4
1090
990
086-B
0.5
1030
930
UNITS
0.6
970
870
1/3 HP
2
036
0.1
1020
1350
960
1210
10 x 8
0.2
1000
1330
940
1170
056 - B
0.3
970
1260
890
1110
070 - B
0.4
940
1210
850
1050
UNITS
0.5
890
1130
790
980
0.6
840
1060
730
900
1/2 HP
4
047
0.1
890
1070
1270
1480
880
1050
1220
1340
11 X 8
0.2
880
1060
1260
1460
870
1040
1210
1330
0.3
860
1020
1220
1400
850
1000
1160
1270
C UNITS
0.4
840
1000
1180
1350
820
980
1110
1210
0.5
810
960
1120
1280
800
940
1070
1160
0.6
760
920
1080
1220
750
890
1010
1090
3/4 HP
4
054
10 x 8
0.2
900
1110
1450
1850
870
1070
1420
1700
4 POLE
0.3
860
1080
1410
1810
840
1050
1380
1650
0.4
830
1040
1370
1760
820
1030
1350
1630
D UNITS
0.5
790
1020
1340
1730
780
1010
1320
1590
0.6
770
990
1320
1700
760
980
1290
1550
HP, Wheel,
Poles, Units
Coil
Size
WITHOUT COIL
WITH COIL
Speed