Maintenance
5‐2
E
2013 Nordson Corporation
All rights reserved
MicroMax
Issued 12/13
P/N 768635_11
S
Check the hopper for foreign materials, empty and clean if necessary.
S
Changes in vibration and noise levels are easily identified as an
indication to possible problems.
S
Record the air flow at regular intervals; thus charted any degradation
of system performance due to cartridge blocking will become
immediately apparent.
S
Signs of powder leakage may be due to the cartridge seal leaking.
Tighten up the cartridge after ensuring seal integrity
S
Cartridges and final filters cannot be manually cleaned but must be
replaced.
S
On units with final filters, powder leakage may not be noticed, but if
adequate records have been kept, the faults will be apparent.
S
These will be damaged if they are stood on or allowed to become
damp. They must be replaced; SMOOTH SIDE UP.
S
Open the drop leg. Using a clean white cloth check for water, oil or
other contaminants. Correct as necessary.
2. Routine Maintenance
Fan Assembly
Cartridges
Fluid Beds (where applicable)
Compressed Air