![Nordson 3000V Series Manual Download Page 36](http://html1.mh-extra.com/html/nordson/3000v-series/3000v-series_manual_1704318036.webp)
Installation
A 1-34
E
2000 Nordson Corporation
All rights reserved
41-3000
V
Issued 5/00
A3EN-04-[3V-A-AAXP]-12
All units are shipped to accept three-phase power. If you are supplying
single-phase power to your unit, use this procedure to modify your unit to
accept single phase power.
CAUTION:
Units with 400 Vac 3 (without neutral) service are
factory-wired for three-phase operation only and cannot be
modified for single-phase operation. If you install a
single-phase voltage plug on a 400 Vac 3 unit, you may
damage the unit or make it inoperable.
1. See Figure A 1-24. Locate the voltage plug on the power board. It is
plugged into connector X3.
4130551
X3
Fig. A 1-24 Location of Voltage Plug on Power Board
Preparing the Unit for
Single-Phase Operation