3. Decide where to install the first hose by referring to the following
table. Choose the instructions that apply to the type of manifold on
your unit.
Type of Manifold
Instructions
Four-port manifold
Use hose port number 1.
Six-port manifold
Use hose port number 1 or 2. If
you plan to install six hoses
(either now or in the future), use
hose port number 1 for the first
hose (see Note A). If you plan to
install less than six hoses, you
can use hose port number 2 for
the first hose.
NOTE A: To install six hoses, your unit must have the ability to heat
six hoses. Check to see if your unit has six hose electrical
receptacles. Units can be ordered with two, four, or six
receptacles.
CAUTION:
Failure to connect the first hose as instructed
creates a dead area where char builds up, causing downtime.
WARNING:
Hose ports that are unused must be closed with a
plug. Removing plugs can cause hot adhesive to spray or flow
from the port and injure operators.
4. Route the hose from the gun back to the unit. Make sure the hose
does not contact sharp or abrasive surfaces. Follow the hose-routing
guidelines shown in Figure A 1-8.
Installing Hoses