www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
EV Series Automated Dispensing Systems
64
Maximum Voltage
Maximum Current
125 VAC
15A
250 VAC
10A
28 VDC
8A
Pin#
Description
1
NOM (Normally open)
2
COM (Common)
3
EARTH (Ground)
2
1
3
Pin 1
Pin 2
Pin 3
+24V
Relay
Ext. Control Port
NOTES:
• Inputs are not polarity-sensitive.
• The optional start / stop box accessory facilitates input / output connections to this port. Refer to “Start / Stop
Box” on page 61 for part numbers.
Pin
Description
1
Ground
2
Start signal
3
Motor power
4
Motion idle
5
Run / Teach
6
Emergency stop
7
Emergency stop
1
7
Technical Data (continued)
Wiring Diagrams
Dispenser Port