15
GB
Minimum distances to
combustible materials
Back 70mm
Side 150mm
CO-content of flue gas
@ 13%O
2
0,09% / 32 mg/Nm3
0,10% / 37 mg/Nm3 (+1)
0,10% / 37 mg/Nm3 (+2)
Flue gas temperature
161 °C
138 °C (+1)
110
°C
(+2)
Thermal output
87,2 kWh, 314 046 kJ
88,6 kWh (+1), 319 245 kJ
90,0 kWh
(+2), 324 443 kJ
Thermal storage
capacity
(+1)
(+2)
100% after 6,7 hrs
50% after 10,6 hrs
25% after 22,6 hrs
100% after 6,9 hrs
50% after 10,4 hrs
25% after 21,7 hrs
100% after 7 hrs
50% after 10,1 hrs
25% after 20,8 hrs
Energy efficiency
87,6%
89,0% (+1)
90,5% (+2)
Nominal heat output
3,9 kW
4,1 kW (+1)
4,3 kW (+2)
Chimney draft
12 Pa
Length of wood logs
500 mm
Weight
ca. 1 330 kg
ca. 1 672 kg (+1)
ca. 2 014 kg (+2)
Load size (kg)
4 kg
Max nr. loads
5
Loading interval
1 / hour
Nr. burning cycles per
24 hours
1
5. Before Installing a new fireplace
Several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed.
Nordpeis AS is not
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
• distance from combustion chamber to combustible/
flammable materials
• insulation materials/requirements between
fireplace surround and back wall
• size of floor plates in front of fireplace if required
• flue connection between combustion chamber and
chimney
• insulation requirements if flue passes through a
flammable wall
Chimney Draft
Compared to older models, the clean burning fireplaces
of today put significantly higher demands on the
chimney. Even the best fireplace will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draft increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the fireplace,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper. The product is type
tested and should be connected to a chimney that is
dimensioned for the smoke gas temperature indicated
in the CE declaration. When necessary, contact a
professional in advance
Attention! It is recommended to use a qualified
professional when installing a new fireplace.
4. Technical information Salzburg XL