15
4. Clockwise/Counter-Clockwise Operation
Set clockwise / counter-clockwise as required.
WARNING:
FAILURE TO FULLY ENGAGE THE CLOCKWISE/COUNTER-CLOCKWISE
OPERATION SELECTOR WILL RESULT IN REDUCED AIR FLOW AND
INCORRECT TORQUE APPLICATION.
5. Setting Torque to Tighten Fastener
The torque created by the PneuTorque
®
depends on
the air pressure setting. All tools are supplied with
setting data that gives the air pressure required to
produce the correct torque output.
Set the torque output as follows:-
1. Use the setting data (supplied) to find the
air pressure to achieve the required torque.
2. With the tool running, adjust the Lubro Control Unit (not included)
until the correct air pressure is shown on the gauge.
IMPORTANT: THE TOOL MUST BE FREE RUNNING WHILE ADJUSTING THE AIR PRESSURE TO
GIVE THE CORRECT SETTING.
IMPORTANT: CHECK THAT THE LUBRO CONTROL UNIT IS SUPPLYING APPROXIMATELY FOUR
DROPS OF OIL PER MINUTE WHILE THE TOOL IS FREE RUNNING
.
FIGURE 7(a)
–
Clockwise
(Lever pointing to the right
)
FIGURE 7(b)
–
Counter - Clockwise
(Lever pointing to the left)
Summary of Contents for PneuTorque PTS-52-500
Page 1: ...OPERATOR S MANUAL PNEUTORQUE PTS Part Number 34438 Issue 2 Original Instructions English ...
Page 2: ......
Page 27: ...25 ...
Page 29: ...27 NOTES ...