8
Air Lubrication
The tool must be used with oil lubrication in the supplied air. This is achieved by using a Lubro Control Unit
(not supplied).
Set the air lubrication:
a. Fill Lubro Control Unit with hydraulic oil (Shell Tellus S2M 32 or equivalent good quality hydraulic
oil).
b. Ensure the tool drive is free to rotate.
c. Run the tool by pressing the trigger.
d. Adjust Lubro Control Unit to supply 6 drops of oil per minute.
e. Release trigger
.
See Lubro Control Unit Operator’s Manual for more details.
Torque Reaction
The reaction bar ensures all reaction forces are contained, so torque reaction is not passed back to the
operator. Several reaction bar styles are available.
Fit reaction bar as detailed below:
Tool Type
Reaction Bar Type
Fitting Instructions
PTM
Cranked reaction bar (standard)
Fit reaction bar / plate (Figure 1-D) over the
drive square to engage reaction splines
Secure with circlip supplied
Single sided reaction plate (option)
Double sided reaction plate (option)
Nose Extension (option)
Fit as instructions supplied with nose
extension
PTME
Nose Extension (standard)
Factory fitted, not removable
TrukTorque
™
Nose Extension (standard)
Factory fitted, not removable
Summary of Contents for PNEUTORQUE PTM