11
Clockwise/Counter-Clockwise Operation
Set clockwise / counter-clockwise as required.
NOTE: This setting only applies to bi-directional tools.
WARNING:
FAILURE TO FULLY ENGAGE THE CLOCKWISE/COUNTER-CLOCKWISE
OPERATION SELECTOR WILL RESULT IN DAMAGE TO THIS PART OF
THE GEARBOX.
Setting Torque to Tighten Fastener
The torque created by the Pneutorque
®
depends on the air pressure setting. All tools are supplied with an Air
Pressure Graph that gives the air pressure required to produce the correct torque output.
Set the torque output as follows:-
1. Use the Air Pressure Graph (supplied) to find the air pressure
to achieve the required torque.
2. With the tool running, adjust the Lubro Control Unit until the
correct air pressure is shown on the gauge.
IMPORTANT: THE WRENCH MUST BE FREE RUNNING WHILE ADJUSTING THE AIR PRESSURE
TO GIVE THE CORRECT SETTING.
IMPORTANT: CHECK THAT THE LUBRO CONTROL UNIT IS SUPPLYING APPROXIMATELY SIX
DROPS OF OIL PER MINUTE WHILE THE TOOL IS FREE RUNNING
.
FIGURE 4(a)
–
Clockwise
(Arrow towards drive square
)
FIGURE 4(b)
–
Counter - Clockwise
(Arrow away from drive square)
Summary of Contents for PNEUTORQUE PTM
Page 19: ...18...