WWW.NORAC.CA
PRECISION
DEFINED
Page
18
Visit
www.solutions.norac.ca
for
more
system
installation
and
troubleshooting
info.
6.4.
Wing
Sensor
Installation
If
installing
a
three
sensor
system,
refer
to
Section
6.4.1.
If
installing
a
five
sensor
system
(severe
terrain
option),
refer
to
Section
6.4.2.
6.4.1.
Installation
of
a
Three
Sensor
System
Each
sensor
has
a
serial
number
stamped
on
the
sensor
housing.
Apply
a
light
coating
of
the
supplied
Permatex
Anti
‐
seize
grease
to
all
threaded
parts
upon
installation.
Figure
15:
Sensor
Serial
Number
Arrangement
The
MAX
Sensors
(E07)
are
mounted
in
the
positions
shown
in
black.
1.
The
sensor
bracket
should
be
oriented
forward
(ahead
of
the
boom).
2.
Typically,
the
best
mounting
location
for
the
outer
wing
sensor
brackets
will
be
near
the
end
of
the
boom
tips,
approximately
two
feet
(0.6
m)
from
the
end.
3.
Mount
the
MAX
sensors
(E07)
into
the
sensor
brackets
with
the
lowest
serial
number
on
the
left
side
and
the
highest
serial
number
on
the
right
side.
Run
the
sensor
cable
through
hole
in
the
back
of
the
bracket.