10
4.3
W
ING
S
ENSOR
I
NSTALLATION
1.
Assemble the Breakaway Sensor
Mounting Brackets (
B11
) as show in
Figure 4
.
Figure 4 – Breakaway Sensor Bracket
Exploded View
To assemble the breakaway sensor
bracket:
a)
Assemble the bolt and nut into the
collar.
b)
Grease the bottom edge of the
collar and the angled tube of the
base.
c)
Place the collar onto the angled tube
of the mounting base.
d)
Install the spring between the collar
and the upper ring of the base.
e)
Insert tube through assembly and
tighten the collar
2.
Mount the sensor bracket onto the
boom.
3.
Optional spacers and plate may be
needed on some booms to prevent
collision between the bracket and boom
during folding.
If possible, mount the sensor
brackets while the booms are in
their folded position to ensure
that they will not interfere with
anything when the boom is
folded for transport.
Mounting the sensor bracket to
the break-away section of the
boom may cause the boom to
drop suddenly as a break-away
occurs. This will occur on
break-away sections which lift
as they break away.
For optimal boom tip
protection, it is recommended
that the sensor be mounted
within approximately two feet
(60cm) of the boom tip.
Figure 5 - Acceptable Mounting
Please refer to the UC4+ Spray Height
Control system warranty at the end of
the
UC4+ Spray Height Control
Operator’s Manual
(
M01
) for
implications.
4.
Mount the NORAC UC4+ ultrasonic
sensor (
E02
) into the sensor brackets.
The sensors should be oriented forward
(ahead) of the boom (
Figure 5
and
Figure 7
).
When installing the UC4+
sensors (E02), start with the
smallest serial number on the
left hand side proceeding to the
largest serial number on the
right hand side (Figure 8).
FRONT