18
4.6.2 Valve Mounting
1.
Mount the NORAC valve (
V01
) on the
sprayer using the valve mounting bracket
(
B10
).
2.
As shown in
Figure 21
, screw short side of
the threaded rods into the bottom of the valve
block at least 3/8". The valve mounting holes
are drilled and tapped 3/8 NC-1" deep.
3.
Tighten the Hex nuts to hold the rods.
4.
Put the mounting bracket on the other side of
the tube and tighten with the spring washers
and the Hex nuts. Cut excess off of the rods,
if necessary.
If using bolts, the bolts should thread
into the valve block at least 3/8". The
valve mounting holes are drilled and
tapped 3/8 NC-1" deep. The rule of
thumb for bolt length is 1-1/2" longer
than the tube size.
You must ensure no hydraulic
components will interfere with any
sprayer parts or be pulled tight at any
time.
The recommended location for the
NORAC valve block is on the rear of
the boom center section on the
horizontal cross member, near the
existing valve block.
Figure 21 – Valve Mounting Location
Figure 22 – Valve Mounting Example
NORAC Valve
Block
Existing Valve
Block
Summary of Contents for UC4+ 1200/1600