Installation Guide

IR Pet Detector

Installation

•  Decide on the location of the Detector and if it is to be corner or surface mounted.

•  After the installation site is selected, follow the steps described above to mount the Detector.

•  Press the Test Button to enter Test Mode. Walk around the protected area noting when the 
 

LED lights up and check that the detection coverage is adequate.

•  When detection coverage is found to be satisfying, installation is now completed.

Installation Recommendations

The Detector is designed to give a typical detection range of 12 meters when mounted at 2 meters above ground.

For Pet-Immune Detector series, it gives a typical PET IMMUNE range of 7 meters when mounted at 1.9 meters above ground.
If mounted higher above ground, it gives a farther PET IMMUNE range.

To take full advantage of Detector, the following guidelines should be considered:

It is recommended to install the Detector in the following locations

•  Mount the detector at 1.9M-2.0M height for best performance:
      

 

<IMPORTANT NOTE>

For the most desirable performance of Pet-Immune Detector series, remember to adjust the height of Detector mounting site with respect to the height 
of the tallest animal in the house. Taller-than-average pets may require the Detector to be mounted higher for the Pet Immunity purpose.

When deciding on the height of the Detector mounting site, remember to take the possible blind spot into consideration. 
The blind spot underneath the Detector enlarges proportionally to the height of the Detector mounting site.

Please note that performance is affected by external factors, such as height of detected object, desired detection range, installation area…etc. 
The suggested mounting height could be adjusted according to actual installation environment factors. 

• 

Mount where the animals cannot come to the detection area by climbing on furniture or other objects.

• 

Don’t aim the detector at stairways the animals can climb on.

• 

In a position such that an intruder would normally move across the Detector’s field of view from side to side.

• 

In a corner to give the widest view.

• 

Where its field of view will not be obstructed e.g. by curtains, ornaments etc.

Limitations

• 

Do not position a Detector to look directly at a door protected by a Door Contact, this could cause the Door Contact and Detector radio signals to be trans-

mitted 
 

at the same instant when entering, canceling each other out.

• 

Do not install the Detector completely exposed to direct sunlight.

• 

Avoid installing the Detector in areas where devices may cause rapid change of temperature in the detection area, i.e. air conditioner, heaters, etc.

• 

Avoid large obstacles in the detection area.

• 

Not pointing directly at sources of heat e.g. fires or boilers, and not above radiators.

• 

Avoid moving objects in the detection area i.e. curtain, wall hanging etc. 

Summary of Contents for IR Pet Detector

Page 1: ...1 NookBox Installation Guide IR Pet Detector NookBox IR Pet Detector P119009 E6309664 Installation Guide ...

Page 2: ...s a tamper switch which will be activated when the cover is opened It can also alert you to signal communication problems and low battery situations The Detector is designed to give a typical detection range of 12 meters when mounted at 2 me ters above ground The Pet Immune models of IR 29 series Detector sensor further support pet immunity feature and will not detect pets of up to 27 kg within 7 ...

Page 3: ...d Factory default for 868WF frequency models 433 FM and 868FM frequency models does not support JP2 Jumper Switch Supervision is enabled and cannot be disabled 4 Sensitivity Increaser Jumper Switch JP3 When set as OFF the Detector s detection sensitivity is in normal level Factory default for non Pet Immune models When set as ON the Detectors detection sensitivity is high Factory default for Pet I...

Page 4: ...ncrease detection sensitivity connect the Jumper Switch JP3 or the ON position Factory default for Pet Immune models To maintain normal detection sensitivity disconnect the Jumper Switch JP3 or the OFF position Factory default for non Pet Immune models Test Mode The Detector can be put into Test mode by pressing the Test Button on the front cover In Test mode it will disable the sleep timer and wi...

Page 5: ...y discharge before inserting new batteries Getting Started Pull out the battery insulator to activate battery The LED indicator will flash for 30 seconds The Detector is warming up During the warm up period the Detector will not be activated It is recommended that you stay away from the detection area during this time After the warm up period is over the LED will turn off and the Detector will be ...

Page 6: ...s shown in the picture Surface mounting I Remove the fixing screw and cover assembly II Break through the knockouts on the inside of base III Using the holes as a template drill holes in the surface IV Insert the wall plugs if fixing it into plaster or brick V Screw the base into the wall plugs VI Screw the cover onto the base Corner mounting I Break through the four corner knockouts II Using the ...

Page 7: ...ose When deciding on the height of the Detector mounting site remember to take the possible blind spot into consideration The blind spot underneath the Detector enlarges proportionally to the height of the Detector mounting site Please note that performance is affected by external factors such as height of detected object desired detection range installation area etc The suggested mounting height ...

Page 8: ...8 NookBox Installation Guide IR Pet Detector For more information visit www getnookbox com ...

Reviews: