4
NookBox
Installation Guide
Siren Indoor
DIP Switch Position Table
Remove the cover by unscrewing the single screw located at the bottom.
In the middle of the L-shaped PCB board, you can see a Jumper Switch
Block which consists of 7 DIP Switches. The function of each DIP Switch
is listed as table right. The DIP Switch is either ON or OFF. Top position
indicates ON and bottom position indicates OFF.
SW1
Siren Learning
OFF
Normal operation
ON
Learn-in mode
SW2
Reserved
SW3
SW4
Siren Duration
OFF
OFF
3 min.
ON
OFF
5 min.
OFF
ON
10 min.
ON
ON
1 second (test)
SW5
Reserved
SW6
Memory Reset
OFF
Normal
ON
Clear Memory
SW7
Supervision
OFF
Supervision function disable
ON
Supervision function enable
* For further detail please see section Function Overview.
Power Supply
The Siren is powered by 4 D-cell alkaline batteries. It also features low battery voltage detection. When low battery is detected, a low
battery signal will be sent to the Control Panel along with regular signal transmissions for the Control Panel to display the status accordingly.
The Siren will also emit 5 beeps when armed/disarmed to notify the user of low battery condition.
Supervision Function
When the Dip Switch #7 is slid to ON position, the Siren will conduct a Self-test Periodically by transmitting a supervisory signal once
every 30-50 mins in normal operation mode.
If this signal is not received, the Control Panel will determine the particular Siren is out-of-order and report the event accordingly.