8
NookBox
Installation Guide
Siren Outdoor
Changing the Battery
Step 1: Disable the Siren Tamper function on the Control Panel (please refer to the Control Panel instruction manual).
The siren will sound a beep to indicate the tamper switch is now disabled.
Step 2: Release the cover-fixing screw at the bottom of Siren using a Philips screwdriver and pull the outer case out carefully.
Step 3: Slide battery switch to the off position.
Step 4: The battery compartment is a large box in the Siren with a lid secured by 2 screws. Release the screws using a Philips screwdriver
and take off the compartment lid.
Step 5: Remove the old batteries and press the Tamper Switch a couple times to discharge.
Step 6: Insert new batteries into the battery compartment.
Step 7: After inserting batteries, slide the battery switch to ON position. All LEDs will flash once and the buzzer will emit 1 beep as the
Siren powers on.
Step 8: Replace and secure the battery compartment lid, with 2 screws using a Philips screwdriver.
Step 9: Replace and secure the Top cover by tightening the bottom screw using a Philips screwdriver.
Step 10: Enter the Control Panel Sound/Siren setting webpage to enable the Siren Tamper function again. The Siren will sound a beep to
indicate the tamper switch is now activated.
Factory Reset
The Siren can be reset and memory contents cleared. Whenever the Siren is removed from the Control Panel, it should be put to factory reset
to clear its Control Panel memory, otherwise the Siren will still raise alarm if it receives alarm signal from panel.
Step 1: Disable the Siren Tamper function on the Control Panel (please refer to the Control Panel instruction manual).
The Siren will sound a beep to indicate the tamper switch is now disabled.
Step 2: Remove the Siren from Control Panel device list (please refer to the Control Panel instruction manual).
Step 3: Release the bottom screw of the Top cover using a Philips screwdriver, remove the top cover..
Step 4: Slide the battery switch to the OFF position.
Step 5: Press and hold the Learn Button and slide the battery switch to BT4 terminal. Continue to hold the Learn Button for 7 seconds.
Release the Learn Button when you hear 2 short beeps and a long beep. The previous parameters in the Siren will be cleared
and it will return to normal mode.