Siren Outdoor
Function Overview
Alarm Memory
If an alarm was triggered in your absence and the system was not disarmed before alarm length expiry, the siren will sound a short alarm when
the system is disarmed to warn the user that an alarm has been triggered when he is away. This suggests that the intruder could still be within
the premises.
Alarm Length
When an alarm is activated by Control Panel, the Control Panel will notify the siren to start alarming according to the panel’s own alarm length
setting. When the Panel’s alarm length expires, it will notify the siren to stop alarm.
If the siren does not receive the Control Panel’s signal to stop alarm, it will sound alarm for a maximum of 3 minutes, then stop the alarm.
For example:
» If the Panel alarm length is set more than 3 minutes, after an alarm is activated, instead of waiting panel alarm length to expire, the siren
will stop alarming after 3 minutes.
» If the panel is under disarm mode and the siren tamper switch is triggered, the siren will activate alarm for 3 minutes since the panel
is under disarm mode and will not activate alarm from tamper trigger.
Siren Tamper
The siren is protected against any attempt to open the lid or to detach the siren from its mounting surface.
If the siren detects a tamper condition, it will activate the siren & strobe light for the programmed alarm period. A tamper signal will be sent
to the Control Panel along with regular signal transmissions for the Control Panel to display the status accordingly. If the tamper condition
persists, the siren will sound a series of five beeps either every time the system is armed or when the tamper is enabled, to indicate a fault.
Tamper feature can be disabled temporaily from the Control Panel using Siren Tamper control function. The siren will stop tamper detection
temporarity for one hour. This function is mainly designed for replacing battery or changing siren installation location. After one hour, The
Control Panel will automatically turn the function back ON after the duration. The tamper detection can also be enabled again manually using
the Siren Tamper function.
Audio & Visual Status Indication
While arming / disarming the system, the siren uses different methods to distinguish various statuses for the user, as listed in the table.
* The Siren Audio indication will be affected by the Confirmation ON / OFF setting. When setting Confirmation to OFF, the confirmation sound will not be
available. Refer to Control Panel Sound/Siren setting for Confirmation function.
Siren Audio
Strobe light indication
Arm/Home
1 beep*
3 LED groups flash once
Disarm
2 beeps*
Sequentially flashes for 1 cycle
Arm (Low Battery)
3 beeps
3 LED groups flash for three times
Disarm (Low Battery)
3 beeps
Sequentially flashes for 3 cycles
Arm (Tamper)
5 beeps
3 LED groups flash for 5 times
Disarm (Tamper)
5 beeps
Sequentially flashes for 5 cycles
Entry/Exit Sound
Count-down beeps