RM-12
CCS Technical Documentation
32
COMPANY CONFIDENTIAL
Issue 1 11/2004
Copyright © 2004 Nokia. All Rights Reserved.
Figure 12: VCO output, 1800 band, ch700, RX on, continuous output
RF test points
RF GSM component alignment
Signal
Test Point
Parameter
Characteristics
Note
Function
TXP
J7300
"1" and "0"
1.8/0 V digital signal
Power amplifier enable
TXA
J7301
"1" and "0"
1.8/0V digital signal
Power control loop enable
RXI/RXQ
J7302/J7303 voltage swing (static)
1.4Vpp
DC level 1.4V
Received demodulated I -and Q signals
RFBus Data J7304
"1" and "0"
1.8/0V digital signal data frequency max. 10MHz RFBUs data; read/write
RFBusClk
J7305
"1" and "0"
1.8/0V digital signal data frequency max. 10MHz RF Bus clock
RFBus Ena1 J7306
"1" and "0"
1.8/0V digital signal
RFBus enable
RESET
J7307
"1" and "0"
1.8/0V digital signal
Reset to Helgo
RX Channel Select Filter Cal RX Cal RX Band Filter Response Cal RX DtoS Balance Cal TX IQ Tuning TX Power Level Tuning
Helgo (N7300)
YES
YES
YES
YES
YES
YES
PA (N700)
NO
NO
NO
NO
YES
YES
ASM (Z7100)
NO
YES
YES
YES
YES
YES
VCO (G7201)
NO
NO
NO
NO
YES
NO
TX SAW (Z7000)
NO
NO
NO
NO
NO
NO
RX LNA (V7100)
NO
YES
YES
NO
NO
NO
RX SAW (Z7101,Z7102,Z7103) NO
YES
YES
NO
NO
NO