NPD-4
Troubleshooting — RF
CCS Technical Documentation
Page 38
Nokia Corporation Confidential
Issue 1 02/2003
Table 11: RF probing for Cell CDMA and PCS back end receiver
Probing point
Probing
location on
board
Probed absolute
power (dBm) or gain/
loss (dB)
Where to start checking if RF
power not correct (soldering,
shorts, DC power applied if
active, correct voltage of DC
signals, otherwise replace)
Alfred (N750)
mixer out= CDMA
RX IF saw (Z753)
in
46, Figure 6
This point not 50
ohms. Will
measure approx -14
dBm for -52 dBm
input and RX AGC
PDM=225.
N750 and supporting components
(Also ensure BAND_SEL low for
Cell CDMA and high for PCS as in
Table 9. Also IF_SEL low for CDMA
as in Table 9), L754, C782, C767,
C761, C786, Z753
CDMA RX IF saw
(Z753) out= Bat-
man (N701) in
47, Figure 6
This point not 50
ohms. Will
measure approx
-47 dBm for -52 dBm
input and RX AGC
PDM=225
Z753, N750 and supporting com-
ponents (including check for proper
voltages on Alfred signaling as in
Table 8), L754, C782, C767, L759,
C770, C771, C772, L760, L761,
N701
Batman (N701)
out= UEM (D200)
in
40, Figure 6
Easiest to use RSSI,
see Table 6.
N701 (VR5, VR7, VIO, ensure 1.35v
on VREFRF01 as in Table 9, also
check RX_IF_AGC as in Table 9),
R705, C704, R706, C706, C701,
C714, R703, R702, C715, R704,
V701, C716, L701, C702
VHF LO at 256.2
MHz
39, Figure 6
N701, C701, C714, R703, R702,
C715, R704, V701, C716, L701,
C702, R705, C706