NHM-8NX
Troubleshooting Instructions
PAMS Technical Documentation
Page 50
ã
Nokia Corporation
Issue 1 05/02
4 Press Stop and you can select to save values to the phone or not
Note: This calibration requires no input signal
RX Band Filter Response
1 Select Maintenance, Tuning, Rx Band Filter Response Compensation
2 Press Start, Read from PM area and you can select to load values from the phone
or not
3 Press Manual Tuning
4 Set the Signal generator according to the pop-up windows
5 When finished press Stop, Write to PM area and you can select to save values to
the phone or not