Nokia Customer Care
3 - Service Software
TFE-4/RV-1
Issue 2.0 Mar/2005
Copyright
©
2005 Nokia Corporation
Page 3-33
Company Confidential
BB ADC-Readings
Test description:
Open the ADC Reading Test Menu from the Testing drop down menu.
Figure 3: ADC-Readings
Perform the Test:
There are no Base band Alignments to be done, only the AD-Values should be read out to
check if the inputs of the AD-Converter have the right levels. The BSI and BTEMP line can
be checked with the Local-Mode switch and the VEB-Power (replacement for the Phone
battery) voltage can be read out. To control this value the real Voltage should be con-
trolled by Voltage-Meter. The Testing Limits can be seen in Table below:
Audio Testing
Test description:
STEP 1:
Prepare Phoenix and Phone:
-Activate Local Mode
AD Channel
Local Switch
Low
High
BSI
Normal
44kR
FLS-4S: 3K
49kR
FLS-4S: 9K
BTEMP
XXX
23°C
27°C
VBAT
XXX
4,1V
4,4V