TFE-4RV-1
Company Confidential
Troubleshooting
Nokia Customer Care
Page 6-18
Copyright
©
2005 Nokia Corporation
Issue 2.0 Mar/2005
Company Confidential
• Enter JBT-9’s Ser.No. (12 digits from the type label) in the field “Counterpart Device
Address”. This has only to be done once as long as JBT-9 will not be changed !
• Standard testing parameters as bit frames, hoping mode and number of bits are
default settings by Phoenix. BT Software Operational Mode = Normal Mode.
• Press the “Run BER Test” button to perform the BER test.
• “Test done” means that test has successfully been performed; if Bit Error Rate is </=
0.1% the “Result” will be also displayed as “OK”.
ADDITIONAL MENU FUNCTIONS
• BT MCM related selftests can be performed by pressing “Run Self Tests”. Result has to
be “OK”
• The “Version Information” dialog gives you BT MCM related detail information that
could be necessary in case of detailed fault reporting.
• Other settings like “Scan Mode” or “BT Software Operational Mode” are only neces-
sary to change in case of special device analysis in combination with e.g. commercial