USE

- First use: in case of electric radiator, drain the warmer befare first use, as explained in the 

draining instructions.
- The working temperatura range of the radiators is between 5°C and 90°C.

- When DUAL FUEL is utilised: make sure the radiator is full of water. One isolating valve should be turned off to prevent circulation 

through the system. Appropriate measures should be also taken to ensure the continuad venting and filing of the product. On no 

account should the electrical option be operated in tandem with central heating

- WARNING: when working, the radiator is hot, especially in chrome finish models. They may cause 

scalds. Keep children away from the warmer. (Fig. 2)

UTILISATION

- Premiere utilisation: Dans le cas d’un radiateur électrique, réaliser une purge du radiateur avant premier usae, comme indiqué sur les 
instructions de purge.
- L’échelle de température d utilisation du radiateur est entre 5ºC y 90ºC.
- En cas de RADIATEUR MIXTE: lorsque que l’élément électrique se met en marche, Veiller a ce que le radiateur soit completement rem-
pli d’eau. 11 est nécessaire d’ouvrir partiellement la vanne de sortie ou détenteur pour permettre l’expansion du liquide, et de fermer 

la vanne d’entrée de maniere a éviter la circulation d’eau a travers le systéme serrer une des valves afin d’éviter la circulation d’eau 

dans le réseau. En aucun cas la résistance électrique ne doit fonctionner en meme temps que le chauffage central

- ATTENTION: lors du fonctionnement, le radiateur est chaud, spécialement pour la finition chromée. 

Cela peut cause r des brulures. Ne pas laisser les enfants s’approcher de trop. (Fig. 2)

UTILIZACIÓN

- Primera utlllzaclón: en caso de que el radiador sea eléctrico, realizar un purgado del radiador 
antes del primer uso, tal y como se indica en las instrucciones de purgado.
- El rango de temperaturas de utilización del radiador es entre 5°C y 90°C.
- En caso de RADIADOR MIXTO: Cuando se ponga en funcionamiento el elemento eléctrico, asegurarse 

que el radiador se encuentra completamente lleno de agua. Se debe dejar parcialmente abierta la 

válvula de salida o detentar para permitir la expansión del líquido, y se debe cerrar la válvula de 
entrada para evitar la circulación de agua a través del sistema. En ningún caso debe funcionar 

simultáneamente la resistencia eléctrica junto con la calefacción central dentro del radiador

- ATENCIÓN: cuando está enfuncionamiento, el radiador está caliente, especialmente en acabado 
cromado. Puede causar quemaduras. No permita que los niños se acerquen mucho a él. (Fig. 2)

USO

Primeiro uso: no caso de o radiador é elétrico, levar a cabo um purgou do radiador antes do primeiro uso, tal e como isto é indicado 
nas ordens de  purgado.
A gama de temperaturas de uso do radiador está entre 5°C e 90°C.
No caso de RADIADOR MISTURADO: Quando ele põe em operação o elemento elétrico, ter certeza que o radiador está totalmente 
cheio com água. Deveria obrir parcialmente a válvula de saída ou segurar para permitir a expansão do líquido, deveria fechar a válvula 

de entrada para evitar a circulação de água pelo sistema. Nunca deveria trabalhar a resistência elétrica simultaneamente junto com o 

aquecimento central dentro do radiador.

ATENÇÃO: quando estiver em operação, o radiador está quente, espacialmente em acabamento cromado. Pode causar queimaduras. 
No permita que as crianças lo manipulen. (Fig. 2)

Summary of Contents for SKY 100048010 N537000001

Page 1: ...Carretera CV 20 km 2 12540 Vila real Castell n Spain Tel 34 964 50 64 50 Fax 34 964 50 67 93 e mail noken noken com www noken com SKY 100048010_N537000001 100048011_N537000002...

Page 2: ...heck the operation of the valves Periodic cleaning and maintenance should be used to avoid the build up of damaging lime scale deposits Bathroom harsh cleaning agent residuals may damage components ma...

Page 3: ...s la prueba total de inmersi n La zona 1 es el rea encima de la ba era o ducha a una altura de 2 25m del suelo En esta zona requieren un ndice de protecci n m nimo de IP44 Si el producto es de un volt...

Page 4: ...aras 0 1 2 e 3 A zona 0 ca dentro da banheira ou mesmo no chuveiro Qualquer produto usado nesta zona deve ser de voltagem baixa m ximo de 12 volts e ser avaliado pelo menos de um IP67 que a con rma o...

Page 5: ...rmica Peso Weight Poids Peso kg Volumen Volume lt R Watt Watt Kcal h Btu h 600 x 475 600 475 50 201 172 685 5 6 1 25 475 x 1000 475 1000 50 372 320 1271 10 2 1 6 Acero al carbono DIN 2394 5 DIN 2394 5...

Page 6: ...6 100048010_N537000001 100048011_N537000002 1 100047112_N598952005 100047112_N598952005 2 100047114_N598952002 100047114_N598952002 3 100048026_N537000003 100048025_N537000006...

Page 7: ...7 1 4 5 2 3...

Page 8: ...patibilidad del radiador con su sistema la responsabilidad recaer sobre el instalador Nunca instale un radiador sin un sellado apropiado INSTALLATION Check the Towel Rail for damage and finish befare...

Page 9: ...seau ouvert eau chaude domestique v rifiez la compatibilit du radiateur avec votre syst me Pour tout renseignement consultez votre installateur Ne jamais installer de radiateur sans raccord appropri I...

Page 10: ...laisser les enfants s approcher de trop Fig 2 UTILIZACI N Primera utlllzacl n en caso de que el radiador sea el ctrico realizar un purgado del radiador antes del primer uso tal y como se indica en la...

Page 11: ...11 80 80 Fig 2...

Page 12: ...while approximately ene hour and when hot liquid will begin to come out through the vent Let all the spare liquid out and when it is all out close the vent quickly Contact between antifreeze liquid a...

Page 13: ...o contr rio Vers o de gua com o radiador em opera o abrir o purgador at que o ar inteiro sai Uma vez comece a deixar gua fechar isto depressa Vers o el trica abrir o purgador e p r a resist ncia em op...

Page 14: ...web For a warranty or other information on this product visit our Web address Pour obtenir une garantie ou d autres informations sur ce produit visitez notre site web Para garantia ou outras informa e...