Parameter 24: Metering Pulse
Whatever other metering reports, this parameter will send one power and one energy report to the lifeline every x s (Seconds). 
Size: 2 Byte, Default Value: 3600

Setting

Description

0

Metering Pulse disable

1 - 65535

Metering Pulse enable and send report every 1 s (to 65535 s)

Parameter 25: Power High Threshold
This parameter defines the High Threshold power value. 
Size: 2 Byte, Default Value: 20

Setting

Description

0

Power High Threshold disable

1 - 65535

Power High Threshold enable with the value from 1 W (to 65535 W)

Parameter 26: Power Low Threshold
This parameter defines the Low Threshold power value. 
Size: 2 Byte, Default Value: 5

Setting

Description

0

Power Low Threshold disable

1 - 65535

Power Low Threshold enable with the value from 1 W (to 65535 W)

Parameter 27: Power Threshold Action
This parameter will define the Micro Smart Plug actions if the power Low and High Threshold are reached.The value may be the sum of available values.
For example, if you want:- Power High Threshold Action is enable and sent ON to Group 4(3)- Power Low Threshold Action is enable and sent OFF to
Group 5 (4)the parameter value must be 3+4=7. 
Size: 1 Byte, Default Value: 7

Setting

Description

0

Power Threshold Action is disable.

1

Power High Threshold Action is enable and send the command OFF to Group 4

3

Power High Threshold Action is enable and send the command ON to Group 4

4

Power Low Threshold Action is enable and send the command OFF to Group 5

12

Power Low Threshold Action is enable and send the command ON to Group 5

Technical Data

Dimensions

0.0440000x0.0440000x0.0780000 mm

Weight

70 gr

Hardware Platform

ZM5202

EAN

3700313920596

IP Class

IP 20

Voltage

230 V

Load

1840 W

Device Type

On/Off Power Switch

Network Operation

Always On Slave

Z-Wave Version

6.51.06

Certification ID

ZC10-16045035

Z-Wave Product Id

0x0165.0x0001.0x0003

Supported Command Classes

Switch All

Summary of Contents for NODEMSP3101

Page 1: ...nd and origin as long as both are suited for the same frequency range If a device supports secure communication it will communicate with other devices secure as long as this device provides the same o...

Page 2: ...nstallation 1 Plug the NodOn Micro Smart Plug on your power outlet 2 Plug the electrical appliance you want to control on the NodOn Micro Smart Plug 3 The Micro Smart Plug allows to switch ON Power ON...

Page 3: ...ings dont work as expected 1 Make sure a device is in factory reset state before including In doubt exclude before include 2 If inclusion still fails check if both devices use the same frequency 3 Rem...

Page 4: ...and 24 Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced...

Page 5: ...cifications This parameter is to set the Alarm 3 Specifications Use the Home Automation Gateway interface or our Alarm set up form to define the value corresponding to your need Size 4 Byte Default Va...

Page 6: ...ing to your need Size 2 Byte Default Value 0 Setting Description 0 65535 To set up your values please follow this link www nodon fr support msp3 alarm Parameter 20 Alarm 8 Specifications This paramete...

Page 7: ...cro Smart Plug actions if the power Low and High Threshold are reached The value may be the sum of available values For example if you want Power High Threshold Action is enable and sent ON to Group 4...

Page 8: ...the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of remov...

Reviews: