Parameter 24: Metering Pulse
Whatever other metering reports, this parameter will send one power and one energy report to the lifeline every x s (Seconds).
Size: 2 Byte, Default Value: 3600
Setting
Description
0
Metering Pulse disable
1 - 65535
Metering Pulse enable and send report every 1 s (to 65535 s)
Parameter 25: Power High Threshold
This parameter defines the High Threshold power value.
Size: 2 Byte, Default Value: 20
Setting
Description
0
Power High Threshold disable
1 - 65535
Power High Threshold enable with the value from 1 W (to 65535 W)
Parameter 26: Power Low Threshold
This parameter defines the Low Threshold power value.
Size: 2 Byte, Default Value: 5
Setting
Description
0
Power Low Threshold disable
1 - 65535
Power Low Threshold enable with the value from 1 W (to 65535 W)
Parameter 27: Power Threshold Action
This parameter will define the Micro Smart Plug actions if the power Low and High Threshold are reached.The value may be the sum of available values.
For example, if you want:- Power High Threshold Action is enable and sent ON to Group 4(3)- Power Low Threshold Action is enable and sent OFF to
Group 5 (4)the parameter value must be 3+4=7.
Size: 1 Byte, Default Value: 7
Setting
Description
0
Power Threshold Action is disable.
1
Power High Threshold Action is enable and send the command OFF to Group 4
3
Power High Threshold Action is enable and send the command ON to Group 4
4
Power Low Threshold Action is enable and send the command OFF to Group 5
12
Power Low Threshold Action is enable and send the command ON to Group 5
Technical Data
Dimensions
0.0440000x0.0440000x0.0780000 mm
Weight
70 gr
Hardware Platform
ZM5202
EAN
3700313920596
IP Class
IP 20
Voltage
230 V
Load
1840 W
Device Type
On/Off Power Switch
Network Operation
Always On Slave
Z-Wave Version
6.51.06
Certification ID
ZC10-16045035
Z-Wave Product Id
0x0165.0x0001.0x0003
Supported Command Classes
Switch All