OPERATING INSTRUCTIONS FOR ‘GE’ CONTROL
CONTROL MODULE type
R80 XSC
designed for use with Nobo Panel heaters using Series 8 controls.
A Control module providing an adjustable temperature range, suitable for standalone and normal applications.
KEY to Fig. 1.
1 – Temperature adjustment control.
6 – Amber operating indicator light.
7 – 7°C. Frost Protection setting.
8 – On / Off switch. l = On, 0 = Off.
OPERATING INSTRUCTIONS
Switch the heater on with switch (8).
Set required temperature with control (1).
When the thermostat calls for heat the amber indicator will also glow.
The action of the electronic thermostat provides proportional regulation of temperature. The Amber operating
indicator light will be seen to go on and off at frequent intervals as it adjusts the amount of heat supplied to
maintain room temperature. When room temperature is more than 1°C below the thermostat set point the
heater will operate continuously but during the last one degree the operation will be proportionally reduced
until the required temperature is achieved.
In a room where more than one heater is used the temperature setting should be balanced so that all heaters
work together. The temperature setting should be made in a warm room and adjustments made until the
surface temperature of all heaters feels equal to touch.
FROST PROTECTION
When the temperature adjustment control (1) is set inline with the frost symbol the heater will operate only
when the temperature falls to below 7°C.
ACCESSORIES
Tamperproof covers are available for the switch and temperature scale mechanisms.
NOTE
The heater should not be covered or things be placed on or over the heater.
The heater is fitted with an over-temperature cut-out which will switch off the heating element in the event of
the heater becoming too hot. The element will not be switched back on again until the heater has cooled.
CLEANING
The heater may be cleaned with a damp cloth and mild detergent.
The heater may be tilted forwards on its mounting bracket for cleaning and decorating behind the heater.
Pressing the clips downward at the back of the heater will release the heater from the mounting bracket.
Telephone: 0121 328 5671 Facsimile: 0121 327 8580
Series 8 - GE.
txt
- 215
Temperature control module.
215
GE