OPERATION
Speed Scrub
r
2001 Electric (04--04)
15
TROUBLE SHOOTING -- CONTINUED
PROBLEM
CAUSE
SOLUTION
Poor water pick up.
Recovery tank is full.
Empty recovery tank.
Ball float shutoff screen inside
recovery tank is clogged.
Remove screen and clean.
Squeegee is clogged with debris.
Clean squeegee.
Squeegee blades are worn.
Replace squeegee blades.
Squeegee thumbscrews are loose.
Tighten thumbscrews.
Vacuum hose connections are
loose or hose has a hole.
Push vacuum hose cuffs firmly on
connections. Replace hose if
damaged.
Vacuum hose is clogged with
debris.
Remove clogged debris.
Tank gasket is defective.
Replace tank gasket.
Recovery tank water inlet is
plugged. Inlet is located at bottom
of recovery tank.
Empty recovery tank and tilt it
sideways to locate inlet hole,
remove clogged debris.
Drain hose plug is loose.
Tighten drain plug.
Clear recovery tank lid is loose.
Tighten lid.
Vacuum motor is loose.
Tighten down vacuum motor. Do
not over tighten and damage motor.
SPECIFICATIONS
Model
Speed Scrub
r
2001
LENGTH
1194 mm (47 in.)
WIDTH
559 mm (22 in.)
HEIGHT
965 mm (38 in.)
WEIGHT
85 Kg (185 lb)
SOLUTION TANK CAPACITY
38 L (10 gal)
RECOVERY TANK CAPACITY
45 L (12 gal)
CLEANING PATH WIDTH
508 mm (20 in.)
BRUSH MOTOR
.75hp, 220 rpm, 120v, 6.5A, 560w
VACUUM MOTOR
1.25hp, 2 stage, 120v, 919w, 7.5A
WATER LIFT
2083 mm (82 in.)
POWER CORD LENGTH
14/3, 23m (75 ft.)
DECIBEL RATING AT OPERATOR’S EAR, INDOORS ON TILE
70dB(A)