OPERATION
14
Speed Scrub
r
2001 Electric (04--04)
STORING MACHINE
1. Drain and rinse tanks thoroughly.
2. Store machine in a dry area with squeegee and
scrub head in the raised position.
3. Remove recovery tank lid to promote air
circulation.
ATTENTION If storing machine in freezing
temperatures, be certain to drain machine of all
water. Damage due to freezing temperatures is not
covered by warranty.
WARNING: Do Not Use Outdoors. Do Not
Expose To Rain. Store Indoors.
RECOMMENDED STOCK ITEMS
Refer to Parts List section for recommended stock
items. Stock Items are clearly identified with a bullet
preceding the parts description. See example below:
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
No power.
Fuse blown or circuit breaker
tripped in building.
Replace fuse or reset breaker in
building.
Power cord disconnected.
Connect power cord.
Faulty extension cord.
Replace extension cord.
Faulty pigtail cord.
Contact Service Center.
Brush motor does not operate.
Faulty brush switch.
Contact Service Center.
Machine circuit breaker has tripped. Clean or replace pad or brush and
reset breaker button.
Rectifier has burned out.
Contact Service Center.
Faulty wiring.
Contact Service Center.
Faulty brush motor.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Vacuum motor does not operate.
Faulty vacuum switch or wiring.
Contact Service Center.
Faulty vacuum motor.
Contact Service Center.
Carbon brushes worn.
Contact Service Center.
Safety lights do not work.
Flasher is burned out.
Contact Service Center.
Little or no solution flow.
Solution flow lever is not activated.
Push solution flow lever forward.
Solution line is clogged.
Remove hose and blow
compressed air through it.
Solution valve is clogged.
Remove valve and clean. Do not
scratch or damage inside of valve.
Solution flow adjustment knob
needs adjusting.
Adjust solution flow knob to
increase solution flow. Turn knob
down to increase flow.