Problem
Cause
Remedy
FaST System does not operate
FaST switch is turned off
Turn on the FaST switch.
FaST circuit breaker tripped
Determine cause and reset the
10A circuit breaker button
Clogged FaST PAK supply hose
and/or connector
Soak connector and hose in
warm water and clean
FaST PAK carton is empty or not
connected
Replace FaST PAK carton and/or
connect supply hose
FaST system is not primed
To prime, operate the FaST solu-
tion system for 5 to 10 minutes.
Clogged flow control
orifice/screen
Remove and clean orifice/screen
Faulty pump or air compressor
Contact Tennant representative
Clogged filter screen
Drain solution tank, remove and
clean filter screen
Faulty detergent timer module
Contact Tennant representative