OPERATION
EZ Rider
t
HP 330780 (12--02)
14
BRUSH DOWN PRESSURE SWITCH
The
brush down pressure switch
controls the
brush down pressure setting. The brush has two
down pressure settings, standard and heavy.
Travel speed and floor conditions will affect the
scrubbing performance. Under normal conditions,
the brush pressure should be set in the standard
setting. Set the brush pressure in the heavy
setting to scrub a heavily soiled floor.
Standard brush pressure setting: Press the top of
the
brush down pressure switch
.
Heavy brush pressure setting: Press the bottom
of the
brush down pressure switch
.
VACUUM FAN/SQUEEGEE SWITCH
The
vacuum fan/squeegee switch
controls the
vacuum fan, squeegee, scrub head, and scrub
brush. The vacuum fan can be operated
separately from the scrub brushes for the purpose
of picking-up excess water without scrubbing, or
double scrubbing without water pick up.
Normal scrub: Press the top of the
vacuum
fan/squeegee switch
. The vacuum fan, squeegee,
scrub head, and scrub brush will start when the
machine moves forward.
Vacuum fan on/squeegee down: Press the
vacuum fan/squeegee switch
in the middle
position.The scrub head will stop and raise.
Vacuum fan off: Press the bottom of the
vacuum
fan/squeegee switch
. The squeegee will raise and
the vacuum fan will stop. There will be a slight
delay before the vacuum shuts off.
NOTE: The rear squeegee will raise and the
scrubbing vacuum will shut off after a short delay
when the machine travels in reverse.
NOTE: The rear squeegee will raise and the
scrubbing vacuum fan will shut off after a short
delay when the scrubbing operations are shut off
with the one step switch.