3.6 EXAMPLES OF CORRECT INSTALLATION
installation of the product (A) necessary for the
horizontal section for connection to an existing
chimney flue. Based on a slope of 3-5%, to reduce
ash deposit in the horizontal pipe section which must
not be over 3m (1). The existing chimney flue must be
inspectionable (2).
Installation of the product (B) requires an insulated
chimney flue
(3) with an internal diameter of no
less than 100mm, since all the smoke piping was
assembled outside the home.
Installation of the product (C) requires a single wall
chimney flue
(4) for the section inside the home.
Relating to the part placed in the attic, you are
advised to install a chimney flue Ø120mm, with
perforation for passage of the piping, extended to:
• minimum 100mm around the pipe if in contact with
inflammable parts such as cement, bricks, etc.;
• minimum 300mm around the pipe (or as described
in the plate data) if in contact with flammable parts
such as wood etc.
In both cases, insert adequate insulation (5) between
the chimney flue and the attic.
You are advised to check and comply with the
plate data of the chimney flue, in particular the safe
distances from combustible materials.
The previous rules also apply for holes made on walls.
On the lower part of the chimney flue, for all
3
installations, a “T” fitting (6) was assembled with an
inspection plug (7), as well as on the inlet of the
chimney flue.
The upper part of the chimney flue, for all
3 installations,
has a wind-proof chimney pot (8) assembled.
In the home, for all 3 installations, a grate is planned
to guarantee correct oxygenation of the premises
where the product is positioned.
Grate not necessary if appliance is hermetically
sealed.
It is not recommended to install a 90° curve as an
initial section which would quickly cause ash to block
smoke passage, causing draught problems in the
appliance.
9
6
7
7
A
1
2
3
3
4
5
8
8
8
6
9
9
6
7
In the event of particular atmospheric conditions
and/or hostile draught conditions, the product can
overcome these situations provided due installation
measures are in place, for example a wind-proof
chimney pot.
B
C
6
Summary of Contents for UNICA 10 C
Page 1: ...EN Installation use and maintenance manual UNICA 10 V C...
Page 37: ...Use and maintenance manual Model UNICA 10 V C 37 ENGLISH ANNOTATIONS...
Page 38: ...Use and maintenance manual Model UNICA 10 V C 38 ENGLISH ANNOTATIONS...
Page 39: ...Use and maintenance manual Model UNICA 10 V C 39 ENGLISH ANNOTATIONS...