PHASE
DESCRIPTION
Management was chosen of the
ambient temperature
using an external thermostat (not
supplied by the manufacturer)
With the COMFORT CLIMA enabled,
the product automatically switches
off on reaching the ambient setting
set (see relative paragraph).
The appliance automatically
manages the power to the fireplace
and ventilation (where present
and enabled) to guarantee better
comfort (see specific paragraph).
The appliance works with ventilation
at the maximum speed to speed up
heating of the environment.
(see rela-
tive paragraph)
The appliance optimises
combustion by reducing the pellet
load, however yield is guaranteed.
THERMOSTAT
COMFORT CLIMA
AUTO
POWERFUL
OPTIMAL FLAME
15 SIGNAL LIST
PHASE
DESCRIPTION
The appliance is in alarm status,
consult the “ALARMS” chapter to for
further details.
The appliance signals an anomaly,
without causing it to switch off. See
“ANOMALY LIST”.
The remote control batteries are
almost flat.
The remote batteries are flat.
Replace them.
The threshold for the working
hours set has been reached. It
is recommended to have the
extraordinary maintenance service
carried out by authorised staff.
ALARM
ANOMALY
BATTERY 10%
FLAT BATTERY
SERVICE HOURS
PHASE
DESCRIPTION
The appliance signals a malfunc-
tion of the sensor controlling correct
combustion. For safety purposes,
while waiting for the technician, the
appliance is set to saving mode.
The maximum smoke temperature
threshold has been reached; the
appliance for a period sets to saving
mode with ventilation at maximum
power to cool the body.
If the quantity of pellets is high for
the power of the machine. In P/E
mix, reduce the pellet load working
on the % (see specific
paragraph)
The appliance signals a malfunction
of the probe detecting the flame.
For safety purposes, while waiting
for technical intervention, the appli-
ance sets to saving mode.
FAULTY PRESS. SENSOR
PHASE
DESCRIPTION
The anomaly is presented when
the user opens the door or ash pan
or pellet door; at this point, pellet
loading inside the brazier stops and
the electronics emit an acoustic
signal. The user, to return to correct
operation, must close the doors. If
this operation is not carried out, the
product will trigger an alarm.
Anomaly of the probe controlling
the temperature of the discharge
smoke, contact the authorised tech-
nician to solve the fault.
The anomalies, unlike alarms, are signals which
automatically reset once the cause that triggered
them has been solved.
Furthermore, signalling will not switch off the
appliance, and normal operation will not be
interrupted.
16 ANOMALY LIST
HOT SMOKE
EXCESS LOAD
S.FLAME FAULT
Some anomalies need technical intervention by au-
thorised staff to be solved. Despite the appliance
continuing to work, the user must ensure the prob-
lem gets solved.
Negligence will cause malfunc-
tioning
.
Summary of Contents for UNICA 10 C
Page 1: ...EN Installation use and maintenance manual UNICA 10 V C...
Page 37: ...Use and maintenance manual Model UNICA 10 V C 37 ENGLISH ANNOTATIONS...
Page 38: ...Use and maintenance manual Model UNICA 10 V C 38 ENGLISH ANNOTATIONS...
Page 39: ...Use and maintenance manual Model UNICA 10 V C 39 ENGLISH ANNOTATIONS...