Use and Maintenance Manual model “B10 V ULISSE”
30
ENGLISH
PHASE
DESCRIPTION
Room temperature management has
been chosen using an external ther-
mostat (not supplied by the manufac-
turer).
With AIR CON. COMFORT enabled,
the product switches off automatically
when set room temperature has been
reached (see specific paragraph).
The appliance manages the fire
-
place power and ventilation au-
tomatically (if applicable) to guar-
antee better comfort (see specific
paragraph).
The appliance works with ventilation
at maximum speed to speed up room
heating. (see specific paragraph).
The appliance optimizes combus-
tion while reducing pellet load,
though yield is guaranteed.
THERMOSTAT
AIR CON. COMFORT
AUTO
POWERFUL
OPTIMAL FLAME
15 ALERTS OVERVIEW
PHASE
DESCRIPTION
The appliance is in alarm
status: see the “ALARMS” chapter to
identify it.
The appliance signals an
anomaly, without switching off. See
“ANOMALY OVERVIEW”.
The remote control batteries are
almost flat.
The remote control batteries are
flat. Replace them.
Working hours threshold has been
reached. It is recommended to re-
quest extraordinary maintenance by
authorized staff.
ALARM
ANOMALY
BATTERY 10%
FLAT BATTERY
SERVICE HOURS
PHASE
DESCRIPTION
The appliance signals a malfunction-
ing of the sensor controlling prop-
er combustion. While waiting for a
technician, for safety purpose, the
appliance switches to saving mode.
Smoke temperature overheating;
the appliance switches temporarily
to saving mode with ventilation at
maximum power to cool the body
down.
If pellet load is too much for the ma-
chine power, reduce it by editing
the load % in P/A RATIO (see specific
paragraph).
The appliance signals a malfunction-
ing of the flame probe. While waiting
for a technician, for safety purpose,
the appliance switches to saving
mode.
S.PRESSURE FAULT
PHASE
DESCRIPTION
This anomaly appears when the user
opens the door, the ash pan or the
pellet door; at this point, pellet load-
ing inside the brazier stops and the
machine emits an acoustic signal.
To restore normal operation, the user
must close the doors. If this opera-
tion is not carried out, the product
will signal an alarm.
Anomaly of the probe controlling
the fume-exhaust temperature,
contact an authorized technician to
solve the fault.
Anomalies, differing from alarms, are signals
which automatically reset once the cause that gen-
erated them has been eliminated.
Moreover, the signalling does not cause the appli-
ance to switch off, thus guaranteeing heating.
16 ANOMALIES OVERVIEW
HOT SMOKE
PELLET OVERLOAD
S.FLAME FAULT
Some anomalies need for technical intervention by
authorized staff o be solved. Despite the appliance
keeps on working, the user must get the problem
solved.
Negligence will cause malfunctioning
.