Read/write registers
48
Readings
To monitor the BOOSTIK LC, click on the
Readings
tab in the right side half of the
Generic UI window to view the contents of read-only registers. For read-only
registers not described in this document, refer to the SDK instruction manual
included with the SDK installation.
Figure 34
Read-only (monitor) registers under the
Readings
tab
Stage one input
monitor
Readings register 10 displays the input power in mW received at the optical input of
the laser amplifier. Before enabling the amplifier emission, ensure the minimum input
power is displayed.
Figure 35
Stage one input monitor
Pump temperature
The hard-coded pump temperature of the BOOSTIK LC is displayed in Readings
register 13. When operating the module is designed to maintain its pump
temperature at this value.
Readings