12
128-191
Segment display
192-255
Dot display
CH15
Red Dimmer
0-255
Dimmer laser output power from 100% to 0%
CH16
Green Dimmer
0-255
Dimmer laser output power from 100% to 0%
CH17
Blue Dimmer
0-255
Dimmer laser output power from 100% to 0%
ILDA control mode
Connect ILDA signal,the lighting fixtures will automatically switchover to ILDA
working mode.This lighting fixtures' ILDA signal cable connection way is compliant
to international standard.
Maintenance
To prolong the life of the product,it is very important to do maintenance work.The
environment is hash outdoors,or if the product is idle for a long time,damp,smoke or
particularly dirty surroundings can cause greater accumulation of dirt on its cover and
housing.So it should be cleaned to maintain an optimum light output and at the same
time to prevent it from corrupted by acid gas.
Cleaning frequency depends on the environment in which the fixture operates.Soft
cloth and typical glass cleaning products should be used for cleaning.It is
recommended to clean product at least once every 20 days.
Friendly notice:Do not use any organic solvent,e.g.alcohol to clean housing of the
apparatus.
Troubleshooting
Problems
Action
The product doesn't
switch on
Power connection is not correct.Re-connect the power.
Power supply is damaged or abnormal.Call a qualified personnel to fix it.
Connection of control board is not correct.Call a qualified personnel to
fix it.
The product can turn
on,but no light coming
Control mode is wrongly setting up.Resetting it according to instruction
book