Chapter 4: Feature Configuration - CLI
Featuring Configuration
– CLI
NGSM48T2 User Manual | 209
Security/Switch>snmp commu add abc
Security/Switch>snmp commu add test 192.168.2.100
255.255.255.0
SNMP Trap Server
Setting
Enter the SNMP Trap Configuration Group
Security/Switch/SNMP>trap
Type 'up' to move up one level or '/' to go to root level
Security/Switch/SNMP/Trap>
Syntax:
Security Switch SNMP Trap Mode [enable|disable]
Security Switch SNMP Trap Version [1|2c|3]
Security Switch SNMP Trap Community [<community>]
Security Switch SNMP Trap Destination [<ip_addr_string>]
Security Switch SNMP Trap IPv6 Destination [<ipv6_addr>]
Example:
Security/Switch/SNMP/Trap>mode ena
Security/Switch/SNMP/Trap>version 2c
Security/Switch/SNMP/Trap>community public
Security/Switch/SNMP/Trap>destination 192.168.2.100
Result:
Trap Mode : Enabled
Trap Version : 2c
Trap Community : public
Trap Destination : 192.168.2.100
Trap IPv6 Destination : ::
SNMP Trap Event
Setting
Syntax:
Security Switch SNMP Trap Authentication Failure