![Niveo NGSM48T2 User Manual Download Page 65](http://html1.mh-extra.com/html/niveo/ngsm48t2/ngsm48t2_user-manual_1696830065.webp)
Chapter 3: Featuring Configuration
– Web UI
Featuring Configuration
– Web UI
NGSM48T2 User Manual | 65
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute:
Get the sample directly.
Delta:
Calculate the difference between samples (default).
Value
The value of the statistic during the last sampling period.
Startup Alarm
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Rising
Trigger alarm when the first value is larger than the rising threshold.
Falling
Trigger alarm when the first value is less than the falling threshold.
RisingOrFalling
Trigger alarm when the first value is larger than the rising threshold
or less than the falling threshold (default).
Rising Threshold
Rising threshold value (-2147483648-2147483647).
Rising Index
Rising event index (1-65535).
Falling Threshold
Falling threshold value (-2147483648-2147483647)
Falling Index
Falling event index (1-65535).
Buttons
Add new entry:
Click to add a new community entry.
Save:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved
values.