background image

 

2.  Turn on the laser level. 
3.  Place the paper sheets on the walls and mark the position of the laser beam. 
4.  Turn off the instrument. Set the instrument in vertical position near to one of the walls.  
5.  Turn on the instrument. 
6.  Mark the position of the laser beam on the paper sheet. Measure the distance 

between the markers 

7.  Do not change the position of the laser and spin it 180°. 
8.  Mark the position of the laser beam on the paper sheet. Measure the distance 

between the markers 

9.  If the distance between the markers is less than 3mm calibration is not necesery. 

 
LASER SENSORS 

 

Nivel System RD100 

 

                                 

 

 

Precise mode   Coarse mode 

 

Too high, 

the laser signal is below  

(please Lower the sensor)  

 - you will hear a high frequency sound 

 
 

You are in the right position 

 - you will hear a continuous sound 

 
           

Too low,  

the laser signal is above 

- you will hear a high frequency sound 

                                                          discharged batteries            buzzer on / off 

 
Sensor panel

 

 
 

 

 

       LCD display 

 

 

 

 

 

 

 

 

 

 

     laser signal receiver 

 
                        ON/OFF button 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

      bracket 

 

 

 

 

 

 

 

 

 

 

 

 

working mode of a sensor  

                               buzzer  

 

 

 

 
 
 
Nivel System RD500 DIGITAL, RD500G DIGITAL 
 
Specification 

-Detecting Range: 300m 
-Unit of display: mm, inch, inch(fraction), cm 
-Segments of indicator: 5+5 

Summary of Contents for NL500

Page 1: ...NL500G Thank you for purchasing a Nivel System NL500 NL500G laser level To best use the purchased instrument please read the instructions carefully and put in a convenient spot so that in the future y...

Page 2: ...2 WARNING The device contains a rechargeable nickel hydrogen batteries which must be recycled and should be disposed in accordance with the requirements WEEE Reg DE23874031...

Page 3: ...to it it s possible to stop the beam at a given distance NL500 NL500G models can be controlled from the device control panel or remotely with remote control Laser level is waterproof and can be used o...

Page 4: ...lean water and consult a doctor Broken or damaged transport box or transport box latches can lead to falling out of the box and damage the laser The collapse of laser level to the ground can lead to d...

Page 5: ...protect from moisture Never put a wet instrument to the transport box wait until dry CONTROL PANEL 10 11 8 6 9 5 7 4 1 2 3 12 Description of buttons and functions 1 ON OFF switch Turns the device on a...

Page 6: ...On the front panel press The instrument will level by itself and the power LED lights up Press the button again to turn off the power Once leveled up the laser LED stops blinking and the laser head r...

Page 7: ...The difference of sensor positions on the staff will indicate the height differences of the measured point compared to the benchmark Slope determination Set the laser level on a tripod Set the laser...

Page 8: ...e the instrument 180 WARNING Be careful not to move the instrument while the head is spinning 5 Turn on the instrument once again and wait until it level automatically 6 Once again mark the position o...

Page 9: ...the markers 9 If the distance between the markers is less than 3mm calibration is not necesery LASER SENSORS Nivel System RD100 Precise mode Coarse mode Too high the laser signal is below please Lowe...

Page 10: ...L 76 W 35 H mm Net Weight 373g with battery Features Easily set up adjust the balance with magnets and vials at both side and top with LCD at both front and back easier for mounting and detecting the...

Page 11: ...r is switched with loudest sound sequence of the switch is loudest no sound normal sound Accuracy switch Detector is switched with highest accuracy sequence of the switch is highest accuracy middle ac...

Page 12: ...sensor digital option NL BR laser bracket Tripod adapter 0 90 Rechargeable battery pack CH 1 charger YR laser shelf TR R TR G laer targets GL R GL G laser glasses Laser case Remote controller SJJ1 tri...

Page 13: ...n of surveying equipment shall not be considered a warranty repair The user shall be charged for unjustified complaints in accordance with the effective price lists Warranty repairs shall be carried o...

Page 14: ...0 C 50 C Power DC 4 8 6 V 4 rechargeable batteries type D NiMH Working time about 30h Battery charging time about 7h Dust and waterproof IP56 Dimensions 206 x 206 x 211 mm Weight 2 8kg Remote control...

Page 15: ...i kujemy za zakupienie niwelatora laserowego firmy Nivel System model NL500 NL500G Aby m c jak najlepiej wykorzysta zakupiony instrument prosimy uwa nie przeczyta instrukcj i po o y w dogodnym miejscu...

Page 16: ...16 UWAGA Urz dzenie zawiera baterie niklowo wodorowe baterie te musz by poddane recyklingowi lub powinny by utylizowane zgodnie z wymogami WEEE Reg DE23874031...

Page 17: ...zyzn laserow dodatkowo urz dzenia wyznaczaj o p aszczyzny laserowej laser liniowy punkt do g ry i punkt do do u Za pomoc laser w mo liwe jest tak e rysowanie linii laserem funkcja skanowania dzi ki cz...

Page 18: ...wynikaj ce z tego powodu straty Niew a ciwe u ycie lasera oraz stosowanie go niezgodnie z opisanymi w tej instrukcji procedurami mo e spowodowa obra enia lub nara enie si na nadmiern dawk promieniowan...

Page 19: ...niew a ciwymi ruchami lub reakcjami na skutek czenia z innymi produktami BATERIE W NL500 500G zastosowano akumulatorki niklowo wodorowe kt re mog by adowane adowanie akumulatork w odbywa si za po redn...

Page 20: ...k w aby wprowadzi spadek w kierunku osi Y 11 Dostosowanie spadku w kierunku osi X kiedy niwelator prze czony jest w tryb r czny u yj przycisk w aby wprowadzi spadek w kierunku osi X 12 System ADS kied...

Page 21: ...chni w osi X Aby ustawi spadek w osi Y naci nij odpowiednio przyciski ka dorazowe przyci ni cie spowoduje pochylanie si wyznaczanej przez laser powierzchni w osi Y System ADS W czenie funkcji spowoduj...

Page 22: ...ak jak na obrazku obok Po w czeniu urz dzenie samo spoziomuje si g owica zacznie obraca si wyznaczaj c p aszczyzn pionow Pionownik laserowy g rny wyznacza lini prostopad do generowanej p aszczyzny las...

Page 23: ...pomi dzy znaczkami z pierwszego i drugiego po o enia niwelatora je li odleg o jest mniejsza ni 6 mm kalibracja nie jest potrzebna w przeciwnym przypadku zalecany jest kontakt z serwisem 8 Wykonaj anal...

Page 24: ...czna CZUJNIKI LASEROWE Nivel System RD100 Wy wietlacz Tryb precyzyjny Tryb zgrubny Za wysoko sygna laserowy znajduje si poni ej obni czujnik s yszalny b dzie d wi k wysokiej cz stotliwo ci Jeste na w...

Page 25: ...dbioru lasera Zakres temperatury pracy 20 C 50 C Wymiary 170 L 76 W 35 H mm Waga z bateriami 373g wy wietlana jednostka strza ki nawigacyjne odchylenie od poziomu wi zki laserowej sygna d wi kowy prze...

Page 26: ...lacza prze cznik g o no ci sygnalizatora poziomu prze cznik trybu dok adno ci pracy magnes y libelka znacznik poziomu Wska nik poziomu LED G rny wska nik LED czerwony wi zka laserowa znajduje si powy...

Page 27: ...ie NL BR uchwyt czujnika Adapter na statyw 0 90 Komplet akumulatork w CH 1 adowarka YR p ka laserowa TR R TR G tarczki laserowe GL R GL G okulary laserowe Waliza transportowa Pilot zdalnego sterowania...

Page 28: ...t u ytkownik zgodnie z obowi zuj cymi cenami Naprawa gwarancyjna dokonana b dzie wy cznie na podstawie dokumentu zakupu W ramach gwarancji Gwarant nie ponosi odpowiedzialno ci z tytu u skutk w usterek...

Page 29: ...g owicy zmienna 0 60 120 300 600 obr min Skanowanie 0 10 45 90 180 Praca w zakresie temperatur 20 C 50 C Zasilanie DC 4 8 6 V 4 akumulatorki typ Ni MH Czas pracy ok 30 godz Czas adowania akumulatork w...

Page 30: ...30 Notatki...

Page 31: ...31...

Page 32: ...32 Nivel System serwis i wsparcie TPI Sp z o o ul Bartycka 22 00 760 Warszawa Polska 48 22 651 03 06 48 22 651 03 09 tpi tpi com pl www nivelsystem com...

Reviews: