TSB132.05 Page 5
Figure 5: Module port caps and plugs.
3. Place the module on the support rack such that the bottom end cap is
supported near its center. Hold the modules in place with the strap(s) that
attach to the support structure. Utilize curved saddles to cushion the modules
to the support rack.
4. If needed, loosen the end clamps such that the upper and lower ports can be
mechanically adjusted to line up with the side ports on the headers. Line up
the ports and then tighten the end cap clamps such that there is no gap
between the metal ends (See Figure 3).
5. Connect all ports starting with the bottom (feed) port and working up. A spool
piece with double Victaulic connections is recommended. Tighten all Victaulic
clamps. Slowly pressurize the system and check for connection leaks.
6. Flush thoroughly with permeate or city water.
Hydranautics
401 Jones Rd.
Oceanside, CA 92058
Tel: (760) 901-2500
Fax: (760) 901-2578