background image

 

 

 

 

 

 

 

 

 

 

Technical Service Bulletin

 

JANUARY 2019    TSB132.05 

 

 

HYDRAcap

 Module Installation Instructions and Rack Design  

This  Technical  Service  Bulletin  provides  information  required  to  install  HYDRAcap

 

Ultrafiltration modules and to demonstrate a sample support rack assembly. 
 

General Guidelines/Rack Design

 

HYDRAcap

 is a stand-alone module capable of withstanding a pressure of 73 psig (5bar) 

at 20°C.  The following rules are applicable to its installation: 

1.  The  modules  should  be  installed  vertically  with  the  filtrate  connection  at  the  top 

(see figure 1).  Vertical installation is highly recommended.  If horizontal orientation 
is  the  only  choice,  the  modules  should  be  placed  with  the  feed  and  concentrate 
ports facing upwards to avoid air entrapment. 

 
 

 

Figure 1: Flow Orientation 

 

2.  Feed water should enter the bottom of the module.  Under certain conditions such 

as  high  solid  loading,  it  may  be  necessary  to  alternate  the  feed  direction  from 
bottom-to-top to top-to-bottom. 

Concentrate 

Feed 

Filtrate 

All Connections 
2” Victaulic 

Reviews: