7
EN
Replacing a torque spring
WARNING
Before attaching or detaching the torque spring, always disconnect the power plug from the outlet.
CAUTION
The spring plate assembly must be oriented correctly.
The ball goes into the recess of the torque adjustment ring. When it is attached in the opposite orientation, the
torque adjustment ring easily gets loose.
Also, when the torque adjustment ring is turned, there will be no clicking sound.
Recommended grease (separately sold)
Idemitsu Kosan Co., Ltd.: Daphne Eponex SR No. 2
Showa Shell Sekiyu K.K.: Alvania Grease S2
Cosmo Oil Co., Ltd.: DYNAMAX No. 2
1
Turn the torque adjustment ring cover counterclockwise to remove
2
Turn the torque adjustment ring counterclockwise to remove
3
Remove the spring plate assembly
→
torque spring
→
plate, in that
order
Recess
Ball
High torque spring at
shipment
Spring plate assembly
Plate
4
Apply grease to the torque spring
5
Replace the torque spring
To reattach, perform the order in reverse.
TV07844-0̲DLV30A-AD̲en-UL.indb 7