ST-P-AS

ANALOGUE-ADDRESSABLE

PHOTOELECTRIC SMOKE SENSOR

INSTRUCTION MANUAL

MARCH 2001

Section 1 - INTRODUCTION

The ST-P-AS is an attractively-styled, low cost, low
profile photoelectric smoke sensor for use with Nittan
'AS' protocol control panels.  This sensor is virtually
identical in function to our 2KH-AS/2KH-AS2LR sensor
and can therefore be used as a direct replacement.

The ST-P-AS has a chemically etched, stainless steel
insect screen therefore reducing the ingress of insects
and airborne contaminants.

The sensitivity of the ST-P-AS is easily confirmed in the
field, using the TT3 or TT4* electronic tester.
* Available early 1998.

ST-P-AS features:

* Optical detector, detecting visible particles
   of combustion

* Low profile, stylish appearance

* Supplied with protective dust cover,
  (remove during commissioning)

* Low monitoring current

* Integral LED fire alarm indicator

* Remote indicator output on standard models

* Easy to disassemble and reassemble for cleaning

* Uses STB-4 & earlier RB-3/RB-6 Bases

* Manufactured to meet the requirements of
  EN54 Part 7.

CONTENTS:-

Section 1

-

Introduction

- Page 1

Section 2

-

Operation

- Page 2

Section 3

-

Sensor Models

- Page 3

Section 4

-

Base Models

- Page 3

Section 5

-

Installation

- Page 3

Section 6

-

Maintenance &
Cleaning

- Page 4

Section 7

-

Specifications

- Page 6

Section 8

-

Environment
Parameters:-

- Page 6

   - Temperature

- Page 6

   - Humidity

- Page 6

Section 9

-

EMC

- Page 6

Section 10 -

Connections

- Page 7

Section 11 -

Dimensions

- Page 7

Summary of Contents for ST-P-AS

Page 1: ... from Nittan UK Ltd called SENSORTEC ANALOGUE The ST P AS is a low cost elegantly designed low profile sensor which is aesthetically pleasing thus enabling it to blend unobtrusively into modern working environments The ST P AS features the very latest technological advancements increasing reliability and performance The ST P AS is compatible with our existing AS protocol and is compatible with lea...

Page 2: ...T3 or TT4 electronic tester Available early 1998 ST P AS features Opticaldetector detectingvisibleparticles of combustion Low profile stylish appearance Supplied with protective dust cover remove during commissioning Low monitoring current Integral LED fire alarm indicator Remote indicator output on standard models Easytodisassembleandreassembleforcleaning UsesSTB 4 earlierRB 3 RB 6Bases Manufactu...

Page 3: ... building work is being completed for example problems of false alarms are likely to occur after commissioning unless cleaning of the sensor is undertaken At commissioning the dust cover should be removed and discarded NOTE THE PLASTIC DUST COVER MUST BE REMOVED FROM THE SENSOR IN ORDER FOR THESENSORTOFUNCTIONCORRECTLY Section 6 MAINTENANCE AND CLEANING Maintenance The ST P AS sensor is a high qua...

Page 4: ...move the optic chamber by gently twisting in an anticlockwisemovement DO NOT DISMANTLE ANY FURTHER iv Examine the optic chamber and the optic s bridge and check for any dust or dirt which may give cause for false alarm If the sensor is very dirty damaged or corroded please return the complete detector to Nittan for service v If the parts of the sensor are still serviceable proceed to clean the out...

Page 5: ... C to 50 Deg C Section 8 ENVIRONMENTAL PARAMETERS TemperatureConsiderations Over the range from 10 deg C to 50 deg C Humidity Relative Humidity of up to 90 measured at 50 deg C non condensing Section 9 EMC Installation The installation shall be in accordance with the regulations either of the approval body for an approved system or otherwise to the national code of practice regulations for the ins...

Page 6: ...correctly read Set each digit on the appropriate eight switches according to the address required 64 8 16 32 4 1 On 2 On 128 Rear of ST P AS Sensor and Address Switch Setting DIL Switch Above switch setting set to address 12 decimal Off Off 64 8 16 32 4 1 On 2 On 128 Above switch setting set to address 26 decimal Off Off 64 8 16 32 4 1 On 2 On 128 Above switch setting set to address 95 decimal Off...

Page 7: ...UCTION MANUAL MARCH 2001 15mm 35mm 104mm NOTE Clear LED denotes Photoelectric sensor Section 11 CONNECTIONS Also suitable for ST I AS and ST H AS sensors Section 12 DIMENSIONS STB 4 base _ 6 5 3 3 6 5 6 3 5 1 1 STB 4 base LED 1 STB 4 base SIG S Low current LED 3mA max STA R1 loop return to control panel ...

Page 8: ...D HipleyStreet Old Woking Surrey England GU22 9LQ United Kingdom Tel 44 0 1483 769555 Fax 44 0 1483 756686 WebSite www nittan co uk e mail sales nittan co uk Quality System Certificate No 041 Assessed to BS EN ISO 9002 ST P AS ANALOGUE ADDRESSABLE PHOTOELECTRIC SMOKE SENSOR INSTRUCTION MANUAL LPCB REF 041c 09 ...

Reviews: