background image

 

 

MAXIMIZER-II rev A

 

1

1

.

.

6

6

 

 

T

T

P

P

S

S

 

 

S

S

i

i

g

g

n

n

a

a

l

l

 

 

I

I

n

n

p

p

u

u

t

t

 

 

The MAXIMIZER-II is designed to work with most 

throttle-position-sensors

 (TPS) and 

wide-open-

throttle

 (WOT) switches. 

1

1

.

.

7

7

 

 

T

T

r

r

i

i

g

g

g

g

e

e

r

r

 

 

I

I

n

n

p

p

u

u

t

t

s

s

 

 

1

1

 

 

&

&

 

 

2

2

 

 

Grounding these inputs is considered the “ON” position. They can be used to enable or disable 
individual stages. See configuration section for more details. 

1

1

.

.

8

8

 

 

G

G

e

e

n

n

e

e

r

r

a

a

l

l

 

 

P

P

u

u

r

r

p

p

o

o

s

s

e

e

 

 

O

O

u

u

t

t

p

p

u

u

t

t

s

s

 

 

1

1

 

 

&

&

 

 

2

2

 

 

These outputs can be used to turn on an LED or small panel lamp (0.5 amps max), automatically 
activate your remote bottle-opener, or automatically purge your nitrous line. They function like an 
internal switch that is open when not active and connected to ground when active. See configuration 
section for more details. 

1

1

.

.

9

9

 

 

I

I

g

g

n

n

i

i

t

t

i

i

o

o

n

n

 

 

R

R

e

e

t

t

a

a

r

r

d

d

 

 

O

O

u

u

t

t

p

p

u

u

t

t

s

s

 

 

1

1

&

&

 

 

2

2

 

 

These outputs can be used to retard timing provided that your ignition system supports this feature. 
They function like an internal switch that is either open or connected to ground when active. See 
configuration section for more details. 

1

1

.

.

1

1

0

0

 

 

B

B

o

o

t

t

t

t

l

l

e

e

 

 

H

H

e

e

a

a

t

t

e

e

r

r

 

 

E

E

n

n

a

a

b

b

l

l

e

e

 

 

I

I

n

n

p

p

u

u

t

t

 

 

Grounding this input is considered the “ENABLE” position for the automatic bottle heater control. This 
feature allows the MAXIMIZER-II to control the bottle heater relay in an attempt to maintain the target 
pressure. See configuration section for more details. 

1

1

.

.

1

1

1

1

 

 

B

B

o

o

t

t

t

t

l

l

e

e

 

 

H

H

e

e

a

a

t

t

e

e

r

r

 

 

C

C

o

o

n

n

t

t

r

r

o

o

l

l

 

 

O

O

u

u

t

t

p

p

u

u

t

t

 

 

This output is used to turn on the bottle heater relay by grounding the negative side of the coil. See 
configuration section for more details. 

1

1

.

.

1

1

2

2

 

 

N

N

i

i

t

t

r

r

o

o

u

u

s

s

 

 

P

P

r

r

e

e

s

s

s

s

u

u

r

r

e

e

 

 

S

S

e

e

n

n

s

s

o

o

r

r

 

 

H

H

a

a

r

r

n

n

e

e

s

s

s

s

 

 

This harness connects directly to the nitrous pressure sensor. See configuration section for more 
details. 

1

1

.

.

1

1

3

3

 

 

M

M

A

A

P

P

 

 

S

S

e

e

n

n

s

s

o

o

r

r

 

 

I

I

n

n

p

p

u

u

t

t

 

 

The MAXIMIZER-II has an integrated 48 psi pressure sensor designed to measure manifold absolute 
pressure (MAP). Connect the flexible hose to your intake manifold after the throttle plate. 

 
Note: The MAXIMIZER-II calibrates the sensor at power up. If your engine is running, the sensor’s 
pressure reading will be outside the expected range and will not be calibrated – which may result in 
an inaccurate reading. This is why it is recommended to connect the MAXIMIZER-II’s power to your 
ignition switch.  

Summary of Contents for MAXIMIZER-II

Page 1: ...ing Caution EXTREME DANGER Caution Do not use or mix any other manufacturer s products with any Nitrous Express products Do not use or mix any Nitrous Express products with any other manufacturer s pr...

Page 2: ...eneral Options Tab 4 2 3 2 Miscellaneous Option Tabs 4 2 4 MAXIMIZER II Configuration 5 2 4 1 General Tab 5 2 4 2 Stage 1 2 Tab 8 2 4 2 1 Time Based Nitrous Configuration 9 2 4 2 2 RPM Based Nitrous C...

Page 3: ...RIVER must be connected to a good ground location that can handle 40 AMPS DO NOT connect to the ECU ground connection While pulsing the solenoids this will generate large amounts of electrical noise t...

Page 4: ...10 0 B Bo ot tt tl le e H He ea at te er r E En na ab bl le e I In np pu ut t Grounding this input is considered the ENABLE position for the automatic bottle heater control This feature allows the MAX...

Page 5: ...t te er ri in ng g U Us se er r D Da at ta a Drag Slide data fields that have this feature have a down arrow button to the right Clicking and holding the button causes a slider bar to appear Moving th...

Page 6: ...the maximum retry count before the software displays a timeout error For most PC s this should be set to 3 Number of retries on CRC error sets the maximum retry count before the software displays a C...

Page 7: ...fjoracing com Wideband AFR System Controller is recommended It will enable the MAXIMIZER II to accurately display and log your air fuel ratio RPM Signal Present allows you to select whether or not yo...

Page 8: ...eature allows you to use the automatic bottle heater control as well as log your bottle pressure A check mark in the box tells the MAXIMIZER II that the sensor is connected and enables the automatic b...

Page 9: ...ype allows you to select the type of transmission manual or automatic If Manual there is no more configuration required for Transmission If Automatic proceed as follows Detect Gearshift Above allows y...

Page 10: ...AT and WOT is used to attenuate the nitrous ramp by as much as 35 TPS Trigger at allows you to set the throttle point above which the nitrous can be turned on EGO Cutoff allows you to set the lean poi...

Page 11: ...to the desired settings or by using the methods described in the Entering User Data section Ramp allows you to set the time taken from the START of the Nitrous to the FINAL This can be set by draggin...

Page 12: ...button green arrow pointing to car To download a configuration from the MAXIMIZER II ensure the MAXIMIZER II is turned on Open a default configuration by clicking on File then New Now click on the DOW...

Page 13: ...Open In the Files of type section select MAXIMIZER II II Logs If the log files do not appear in your window you may not be in the correct directory To change directories click on the down arrow in the...

Page 14: ...area to be zoomed To zoom out click on the Unzoom button that appears in the upper right when you zoom in Additional features are available to customize the graph view as well as export the screen to...

Page 15: ...does not warrant equipment parts or components purchased by FJO or the customer from any third party manufacturers or suppliers Rather for any defect in respect of equipment parts and components purch...

Page 16: ...14 MAXIMIZER II rev A 6 6 1 1 S Sy ys st te em m...

Page 17: ...15 MAXIMIZER II rev A 6 6 2 2 S St ta at tu us s L LE ED D 6 6 3 3 1 12 2 v vo ol lt t A Ar rm mi in ng g S Sw wi it tc ch h...

Page 18: ...16 MAXIMIZER II rev A 6 6 4 4 I Ig gn ni it ti io on n R Re et ta ar rd d 6 6 5 5 R Re em mo ot te e B Bo ot tt tl le e O Op pe en ne er r...

Page 19: ...17 MAXIMIZER II rev A 6 6 6 6 A Au ut to om ma at ti ic c P Pu ur rg ge e 6 6 7 7 F Fu ue el l P Pr re es ss su ur re e S Sa af fe et ty y C Cu ut t o of ff f S Sw wi it tc ch h...

Page 20: ...figuration to 4 5 volts the TPS TRIGGER to 95 and the IDLE to 0 5 volts Figure B illustrates how to connect a GROUND wide open throttle switch Set the WOT setting in the MAXIMIZER II configuration to...