eNBioAccess-T1 User Guide
17
(138-827) (Bangi-dong, Hyundai Topics Building) 4
th
Floor, Wiryeoseongdae-
ro, Songpa-gu, Seoul, Korea
Tel : 82-2-6488-3232 , Fax : 82-2-6488-3099,
E-Mail: [email protected]; http://www.nitgen.com
3.3. Terminal Setting
3.3.1. Setting via “iAccess
Plus
”
Select [Setting] on the bottom right, and the following screen will appear.
To change the terminal settings, press the [Edit] button on the top
right to switch to the edit mode.
When the terminal settings are finished, press the [Save] button to
save the changes and exit the setting.
Terminal Name
The name of the terminal will be displayed.
LFD Level
The fake fingerprint is likely to be recognized. Therefore, the higher level of security application may be
used. The higher security level may need the longer time to verify the fingerprints of some registered
users.
The security level for the stage of 0-3 is supported.
Door Open Status 1
Set when connecting external contacts.
Settings
Display Method
No Use
No external lock is used.
Normal open
When the power is applied, the lock is open.
Normal close
When the power is applied, the lock is closed.
Door Open Interval
The unlock time can be set from 0.1 to 20 seconds.