background image

Ningbo Ginlong Technologies Co., Ltd.

No. 57 Jintong Road, Binhai Industrial Park, 

Xiangshan, Ningbo, Zhejiang, 315712, P.R.China

Tel: +86 (0)574 6578 1806 

Fax: +86 (0)574 6578 1606

Email: [email protected]

Web: www.ginlong.com

Please record the serial number of your inverter and quote this when you contact us.

Solar PV Grid Tie Inverter

Installation and Operation Manual

Ver 1.0

 2013, Ningbo Ginlong Technologies Co., Ltd.

C

inverter

-2.5K-2G

Summary of Contents for Solis-2.5K-2G

Page 1: ...P R China Tel 86 0 574 6578 1806 Fax 86 0 574 6578 1606 Email info ginlong com Web www ginlong com Please record the serial number of your inverter and quote this when you contact us Solar PV Grid Tie...

Page 2: ...up and Stop 5 1 Starting the Inverter 5 2 Stopping the Inverter 6 Operation 6 1 Main Menu 6 2 Information 6 3 Settings 6 3 1 Setting Time 6 3 2 Setting Address 6 3 3 Clearing Energy 6 3 4 Restoring Se...

Page 3: ...ndicates important safety instructions which if not correctly followed could result in electric shock causing serious injury or death CAUTION CAUTION HOT SURFACE symbol indicates safety instructions w...

Page 4: ...chnician only Warranty may be void if unauthorized removal of cover CAUTION Solis 2 5K 2G has a heat sink on its top surface which helps in cooling down the internal components The heat sink can reach...

Page 5: ...ed supplying power The inverter is initializing Alarm or fault condition is detected The inverter stores the last 10 messages The inverter is operating properly Status ON OFF ON OFF OFF ON FLASHING Li...

Page 6: ...ical position as shown in Figure 4 1 The steps to mount the inverter to the wall are given as follows WARNING 9 10 NOTE Nothing should be stored on or placed against the inverter NOTE Heat sink must b...

Page 7: ...or coat see Figure 4 5 ii Insert the wire into the bottom part of the connector coat as shown in Figure 4 6 Figure 4 5 Disassemble the Connector Cap Figure 4 6 Insert the Wire into the Connector Cap i...

Page 8: ...tor as shown in Figure 4 12 b Put the terminal cap on the terminal as shown in Figure 4 13 Figure 4 12 Connect Wires to the Grid Terminal Figure 4 13 Put the Cap on the Terminal c Connect the AC grid...

Page 9: ...side of Solis 2 5K 2G have power presented the inverter will prepare to generate Initially Solis 2 5K 2G will check both its internal parameters and the parameters of the AC grid to ensure that they a...

Page 10: ...gs 6 2 Information The Solis 2 5K 2G main menu provides access to operational data and information The information is displayed by selecting Information from the menu and then by scrolling up or down...

Page 11: ...ss the ESC key to cancel the change and return to the previous menu 6 3 3 Clearing Energy This function is used to clear energy total energy this month energy and last month energy When Clear Energy i...

Page 12: ...ersion The screen shows the model version and the software version of Solis 2 5K 2G see Figure 6 12 Model 07 Software Version 8E06 Figure 6 12 Model Version and Software Version 6 4 5 Communication Da...

Page 13: ...ms Press the ENTER key to edit the highlighted item Press the UP DOWN keys again to change the setting Press the ENTER key to save the setting Press the ESC key to cancel the change and return to the...

Page 14: ...able 8 1 turn off your inverter refer to Section 5 2 to stop your inverter and wait for 30 minutes before restarting it refer to Section 5 1 to start your inverter If the failure has not been cleared...

Page 15: ...c injection current Rating grid frequency Ef ciency Protection Size Weight Topology Internal consumption Running temperature Ingress protection Interface Design lifetime 2 5kW 2 8kW 230Vac 180 270Vac...