12
KFISH/01/19.11.2018
Don’t reuse the used filter by cleaning again.
Just use the filters which are produced by manufacturer otherwise the device can be
harmed.
Never use device without filter.
Ø
Because of using frequently and disinfection processes of nebulizers and accessories
plastic parts exposure fray. This can change the aerosol specialities which is coming
from medication cup and effects the inhaling negatively. For this reason it is
recomended to change medication cup, masks, air-tube and mouthpiece after 1 year.
Ø
Please protect the device, mediction cup and accessories against hard impulse.
Otherwise this can couse damage and device will become useless.
Ø
Clean the device and its parts before every usage.
Ø
Do not extract, fix or any change on device otherwise this can cause electric shock, fire
or leckage.
Ø
Never use the device if it is damaged or fall in to water.
If any problem occures while using the device first check the troubleshooting. If
problem continuous apply to the authorised service.
9.
Device’s Technical Datas
Ø
The device is manufactured in compliance with EN 13544-1:2007+A1:2009 standards for
airway treatment devices.
Ø
The nebulisation system datas are given in the table in down side.
MMAD (Particle size)
4.7
±30%µm
Nebulisation Rate
>0.3 ml/min
GSD (Geometric Standard Deviation)
4,77
Particle Size Under
5 µm
~%50
13
KFISH/01/19.11.2018
Ø
The horizontal axis is the particle size value, the value is logarithmic distribution;
The left vertical axis is the cumulative percentage of the volume, corresponding to
the rising trend of the curve.
Ø
The small particle size (MMAD) for 50% cumulative particle mass indicates that the particle
sizes at the aerosol from the nebulizer outlet can reach the lower airways.
Ø
In the nebulizer, the particles in the range of 5
µm
constitute approximately 50% of the aerosol
output and more.
Ø
GSD shows aerodynamic particle size distribution and is calculated as 4.77 for Nebulizer.
0
10
20
30
40
50
60
70
80
90
0,1
1
10
CU
MU
LATİ
VE
P
ROBA
BİLİTY LE
SS
TH
A
N
S
TA
TED
Sİ
ZE
%
PARTİCLE SİZE (Μ
M)
1. Test
2. Test
3. Test
4. Test
5. Test
14
KFISH/01/19.11.2018
10.
Keeping and Transporting
Ø
The device can be kept with its package in well aired room humid is not more than %10-
95 and the temperature between -25-70 °C.
Ø
Under this storage condition explained up this device can be kept for 10 years.
Ø
While carrying protect the package from getting wet, impacts and being crushed.
Keep the device away from children.
Keep the device away from direct sunlight and abrasive gases.
Package Contents:
o
HNK-NBL-FISH Compressor Nebulizer.
o
User Manual.
o
Warranty.
Accessories inside the case
o
Medication Cup (1 Pcs)
o
Adult Mask (1 Pcs)
o
Child Mask (1 Pcs)
o
Mouthpiece (1 Pcs)
o
Air Tube (1 Pcs)
o
Spare Air-Filter (5 Pcs)
15
KFISH/01/19.11.2018
11.
Troubleshooting
Problem
Solutions
Device’s On/Off key
is 1 position but
doesnt work.
F
Check the power cable is plugged or not.
F
Check the device’s body is overheated or
not. If overheated
too much unplug and wait for cooling.
Low aerosol or there
is no aerosol.
F
Check the medicaiton cup is filled with water soluable and
true medication.
F
Check the medication cup is filled up with right size of
medicine.
F
Check the connection between device medication cup and
tube is correct or not.
F
Check the medication cup has right connection to device.
F
Check air-tube has no blockage.
F
Medication can be blockaged. Clean it as it is explained in
chapter 7 “Cleaning and Disinfection”
F
Check the medication cup is in vertical position or not.
F
Check the air-tube is straight or not.
F
The device can be clogged air filter, please check.
Device overheats too
much
F
Check the air channels on the device is clear and open.
Don’t cover the device with any c
loths.
F
In long inhaling process break for some time and then
continue inhaling.
If these suggestions doesn’t solve the problem please don’t try to fix it and ask help
form authorized service.
12.
Warranty Contitions and After Sales Support
The
device’s warranty duration is 2 years after purchasing.
!
If you follow the instructions in manual and charge and decharge it properly the
durable period will be 10 years for this device.
!
Warning: The warranty will be invalid if the device is harmed, fixed or opened by
user.
!
Note: Please do not forget to take the warranty and sales receipts and keep them.