INSTALLATION

Feed Connection

Fig.1

A

B

Options

1.  Locate and turn off the angle stop valve on the cold water line feeding the sink where the Sierra

unit is to be installed.  This valve will usually be located under the sink on the pipe coming out of

the wall.

Hint: Be sure to make this connection on the COLD water feed, not the HOT water feed.  If

you are not sure which line is the cold water line, open the hot water tap on the sink until

hot water flows from the faucet.  The hot water line under the sink can then be identified

by touch.

2.  When the angle stop valve is closed, relieve pressure in the line by

opening the cold water tap on the sink.

3.  It may be possible to install the feed adapter fitting at either the

angle stop valve or at the faucet inlet connector depending on the size

and type of fittings at your location.  The angle stop valve is prefer-

able because of its easier accessibility. Both options are given in Fig 1.

Option A - To install the feed adapter at the faucet connector discon-

nect the cold water feed line where it connects to the faucet inlet

connector.  This will usually require an open end wrench, pliers, or

long reach faucet wrench.  Proceed to step 4.

Option B - To install the feed adapter at the angle stop valve, discon-

nect the feed line at the angle stop valve.  This will usually require a

wrench or pliers.  With this end of the water line free, proceed to step

4.

4. Take the 1/4" feed connector valve from the parts kit and install it into the brass feed connec-

tor adapter.  Use a crescent wrench or open-end wrench to tighten the valve into the adapter

(Option B shown in Fig. 1).  If the feed adapter is to be installed at the faucet inlet connector

(Option A shown in Fig. 1) it may be necessary to install the feed connector valve after step 5 due

to limited space.

5. Using the flat and cone washers as necessary, install the feed adapter into the faucet inlet

connector or angle stop valve as chosen above.  Then reconnect the cold water feed line to the

open end of the feed adapter.  Tighten all connections securely.

6. Using the green tubing, install the brass nut, then the plastic ferrule and plastic tube insert.

Secure the tubing into the feed connector valve. Tighten the tubing retaining nut securely.  See

Fig. 2.

7. Obtain the small feed valve warning tag from

the parts bag and attach it by its wire ties to the

feed valve.

3

Fig. 2

INSERT

FERRULE

  NUT

TUBING

5

Rub-

ber

Washer

Angle

Stop

Valve

Std. Feed

Connec-

tor

Shut-

Off

Valve

Summary of Contents for Cascade NS-14

Page 1: ...DRINKING WATER FILTRATION SYSTEM 41840 McAlby Ct Ste A Murrieta CA 92562 800 451 9343 Email cascade nimbuswater com Owner sManual InstallationGuide ...

Page 2: ... block carbon filters These cartridges work together to remove sediment and chlorine taste and odor from your tap water They must be replaced every 6 12 months The chart below gives a general replacement timetable Instructions for cartridge replacement can be found in Section 9 of the Installation Guide Any significant change in performance of the system should be investi gated promptly to avoid s...

Page 3: ...ne expenditures or other losses of this nature Some states do not allow the exclusion or limitationofincidentalorconsequentialdamages sothisexclusionmaynotapplytoyou Owner s Warranty Responsibilities Under the provisions of the Warranty the owner is expected to perform scheduled maintenance as described in this Manual Neglect improper maintenance abuse or unapproved modifications may invalidate th...

Page 4: ...common hand and power tools Improperly installed systems could result in water damage due to leaks or flooding The connection parts kit supplied with the Cascade Drinking Water Filtration System includes compo nents which represent the most common under sink plumbing connections currently in use within the United States If these components do not match the type of connections installed at your loc...

Page 5: ...d faucet base 3 Faucet base Gasket 4 Large slotted washer 5 White plastic spacer 6 3 8 washer 7 Mounting lock nut 8 Quick connect fitting Parts bag may contain items not needed for this system configuration Not Shown 4 blue tubing 4 green tubing Date of Installation Labels 3 Feed Valve Warning Tag Feed Shut off Warning Label Self tapping Mounting Screws 2 4 1 2 3 4 E PushHandle 1 2 3 4 5 6 7 8 ...

Page 6: ... pliers or long reach faucet wrench Proceed to step 4 Option B To install the feed adapter at the angle stop valve discon nect the feed line at the angle stop valve This will usually require a wrench or pliers With this end of the water line free proceed to step 4 4 Take the 1 4 feed connector valve from the parts kit and install it into the brass feed connec tor adapter Use a crescent wrench or o...

Page 7: ...s connection should be hand tightened only Push one end of blue tubing forcefully into quick connect side of the fitting 8 5 Insert tubing and faucet assembly down through the sink hole 6 Position the faucet to the desired handle orienta tion From underneath the sink slip the slotted washer 4 between the white plastic spacer and the sink Securely hand tighten the mounting nut 7 7 Apply a small amo...

Page 8: ...tubing from the faucet assembly to the blue coded connector marked Feed on the top of the manifold unit 3 Take the green tubing already connected to the water feed valve and run it to the manifold unit arranging the lie as desired Trim the end of the green tube as described in step 5 above then insert it into the green coded connector Push the tubing approximately 1 2 into the connector until full...

Page 9: ...ubing and connections for several minutes to detect any leaks Allow the faucet to run for at least 3 minutes then close the faucet A small amount of carbon fines may be seen in the initial flushing of the system 4 Check fittings again for leaks after closing the faucet INSTALLATION Activation Flushing 6 1 Cascade unit is located where it will not be subject to physical impacts or rough contact by ...

Page 10: ...he clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors Press top or bottom of cartridge to engage connec tors until it snaps into place properly 6 Close the dispensing faucet Turn on feed water valve Observe system for any leaks especially at newly replaced cartridge 7 If the replaced cartridge was a carbon filter open the dispens...

Page 11: ... NimbusWaterSystems2003 P N 102863 ...