Fill up fuel tank
With the machine cold, turned
off and disconnected from power
supply:
1. Fill fuel tank from a clean
container with a fresh fuel,
heating oil, DIN 51603-1
(without bio diesel) or Die-
sel EN 590 (Diesel with a bio
diesel content up to 7%). or
fuel type recommended by
your distributor. Tank capac-
ity see Technical data.
NOTE
!
At temperatures below 8°C
(46°F), the fuel oil begins to so-
lidify (paraffi n precipitation). This
can lead to diffi culties in starting
the burner.
Diesel according to EN 590 (up to 7% bio diesel) can be used with the following restrictions:
•
Maximum storage time in high pressure cleaner diesel tank: 1 month.
•
Diesel stored externally for more than 6 months is not allowed to be filled into Nilfisk-ALTO high
pressure cleaners.
•
Diesel EN 590 is not recommended for use in HPW's at an ambient temperature below 0°C.
•
Diesel EN 590 from an open container must not be used.
•
The fuel must be free from contamination.
Before the winter months it is
recommended that a fuel condi-
tioner/stabilizer be added (avail-
able from the fuel oil trade).
3.8 Connecting the high pres
sure hose
3.8.1 Machines with high
pressure hose reel
1)
1. Connect the high pressure
hose quick connector to the
high pressure nipple (A) lo-
cated at the hose reel axle.
2. Place the high pressure hose
into the hose guide (B) and
ritain it with the clip.
3. Release the brake (C) on the
hose reel and wind up the
high pressure hose.
3.8.2 Machines without high
pressure hose reel
1. Connect the high pressure
hose quick connector to the
high pressure nipple located
at right rear of machine above
chemical tank.
A
B
C