Function
NEPTUNE 5 FA_EN_Ver.2.0_25/11
A
B
C
The by-pass pressure is determined of the spring tension in valve ”A”.
The tension is fixed and will bring out a by-pass pressure in about 30 - 35 bar.
Valve ”A” also secures the self suction ability.
The cut off pressure when the gun is released, is determined of the adjustment screw ”B”.
When the screw is tightened the cut off pressure will rice and by loosening it the pressure will
drop.
The safety valve ”C” has no function under normal circumstances. The pressure of the safety
valve is set to about 25 - 30 bar above the cut off pressure.
The safety valve will open if the by-pass valve is stocked and lead water to the suction side of
the pump.
A
B
I
C
D
E
F
G
H
K
When the water regulation ”G” is turned counter clock wise, the seat ”H” opens and the
water runs both to the outlet of the by-pass housing and in by-pass to the suction side of
the pump.
The pressure ”K” will drop depending of the size of the opening in seat ”H”.
Fig.D.8: Water reduction
Fig.D.7: By-pass pressure
Summary of Contents for NEPTUNE 5 FA
Page 1: ...Service Manual NEPTUNE 5 FA NEPTUNE 5 FA_EN_Ver 2 0_25 11 ...
Page 54: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 54 ...
Page 55: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 55 ...
Page 56: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 56 ...
Page 57: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 57 ...
Page 58: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 58 ...
Page 59: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 59 ...
Page 60: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 60 ...
Page 61: ...H Wiring diagrams NEPTUNE 5 FA_EN_Ver 2 0_25 11 61 ...