17
EN
INSTALLATION, USE AND MAINTENANCE MANUAL
4. MAINTENANCE
ATTENTION: Before carrying out any maintenance operations it
is compulsory to unplug the unit from the 230 V the power supply
wall socket and to put on protective gloves and a facemask.
A
For versions with a user interface, the machine indicates when the dust container must
be emptied or the filter cleaned after a time interval that is programmed by the user
(for programming instructions see chart on page 20).
4.1 Emptying the dust container
• The dust container must be emptied regularly every – months, depending on frequency of use and
acquired experience.
• The dust container must be washed with water at least once a year. Dry it thoroughly before replacing it.
INSTRUCTIONS
1. Unplug the unit from the 20 V power supply wall socket
2. Open the dust container by releasing the left-hand and right-hand hooks. Then press the central button
(A) to release the handle and obtain opening of the container downwards (B).
. Remove the dust container (C) from the main vacuum unit body, pulling it towards yourself.
. Remove the cone, dispose the full bag and insert the new bag with the bag stretcher inside it. Set the
cone in place again.
5. Check the condition of the filter cartridge, and clean and wash it if necessary (Chap. 4.2).
. Replace the dust container in the side hooks of the handle, and close it with a slight pressure of both
hands (D) to the sides of the central button.
7. Connect the unit to the power supply socket and press Reset for seconds until stand-by appears
again.
B
C
D